Ultra-High Mass Resolving Power, Mass Accuracy, and Dynamic Range MALDI Mass Spectrometry Imaging by 21-T FT-ICR MS.

Andrew P Bowman, Greg T Blakney, Christopher L Hendrickson, Shane R Ellis, Ron M A Heeren, Donald F Smith

Open access · hybridAbstract read
In one paragraph

Article in Analytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 55 papers.

0numbers the graph read from it
0cells of the map it votes in
55citing papers in PubMed
8.9field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

55 citing papers in PubMed, 118 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. New Analytical Technologies to Resolve, Interpret, and Understand Lipid Complexity.Annual review of analytical chemistry (Palo Alto, Calif.) · 2026
    Review
  6. Article
  7. Article
  8. Article
  9. High-Specificity and Sensitivity Imaging of Neutral Lipids Using Salt-Enhanced MALDI TIMS.Journal of the American Society for Mass Spectrometry · 2025
    Article
  10. Mass Spectrometry Imaging.Analytical chemistry · 2025
    Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Andrew P BowmanMaastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry (IMS) , Maastricht University , Universiteitssingel 50 , Maastricht 6629ER , The Netherlands.
Greg T BlakneyMaastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry (IMS) , Maastricht University , Universiteitssingel 50 , Maastricht 6629ER , The Netherlands.ORCID 0000-0002-4205-9866
Christopher L HendricksonNational High Magnetic Field Laboratory , Florida State University , 1800 East Paul Dirac Drive , Tallahassee , Florida 32310-4005 , United States.
Shane R EllisMaastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry (IMS) , Maastricht University , Universiteitssingel 50 , Maastricht 6629ER , The Netherlands.ORCID 0000-0002-3326-5991
Ron M A HeerenMaastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry (IMS) , Maastricht University , Universiteitssingel 50 , Maastricht 6629ER , The Netherlands.ORCID 0000-0002-6533-7179
Donald F SmithNational High Magnetic Field Laboratory , Florida State University , 1800 East Paul Dirac Drive , Tallahassee , Florida 32310-4005 , United States.ORCID 0000-0003-3331-0526
Maastricht University · NLFlorida State University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Detailed characterization of complex biological surfaces by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) requires instrumentation that is capable of high mass resolving power, mass accuracy, and dynamic range. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) offers the highest mass spectral performance for MALDI MSI experiments, and often reveals molecular features that are unresolved on lower performance instrumentation. Higher magnetic field strength improves all performance characteristics of FT-ICR; mass resolving power improves linearly, while mass accuracy and dynamic range improve quadratically with magnetic field strength. Here, MALDI MSI at 21T is demonstrated for the first time: mass resolving power in excess of 1 600 000 (at

Identifiers

PMID31955581
PMCPMC7031845
OpenAlexW2998799555

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.