Evidence map›Paper›PMID 31955505›Full record

ArticleJournal of clinical hypertension (Greenwich, Conn.)2020

The first study comparing a wearable watch-type blood pressure monitor with a conventional ambulatory blood pressure monitor on in-office and out-of-office settings.

Kazuomi Kario, Daichi Shimbo, Naoko Tomitani, Hiroshi Kanegae, Joseph E Schwartz, Bryan Williams

Open access · greenAbstract read
In one paragraph

Article in Journal of clinical hypertension (Greenwich, Conn.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 55 papers.

0numbers the graph read from it
0cells of the map it votes in
55citing papers in PubMed
10.9field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

55 citing papers in PubMed, 102 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
  11. Article
  12. Article
  13. [Wearable devices: Perspectives on assessing and monitoring human physiological status].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023
    Review
  14. Social jet lag and morning blood pressure surge-central nervous system matters?Hypertension research : official journal of the Japanese Society of Hypertension · 2023
    Article
  15. Review
  16. Digital hypertension towards to the anticipation medicine.Hypertension research : official journal of the Japanese Society of Hypertension · 2023
    Review
  17. Article
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 3 countries.

Kazuomi KarioDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.ORCID 0000-0002-8251-4480
Daichi ShimboThe Hypertension Center, Columbia University Medical Center, New York, NY, USA.
Naoko TomitaniDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.
Hiroshi KanegaeDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.
Joseph E SchwartzColumbia University, New York, NY, USA.
Bryan WilliamsInstitute of Cardiovascular Sciences, University College London, London, UK.
Jichi Medical University · JPColumbia University Irving Medical Center · USStony Brook University · USUniversity College London · GB

Funding

Medical Research Council MC_PC_13090
6 · The paper itself

Abstract

Wearable blood pressure (BP) monitoring devices which measure BP levels accurately both in and out of the office are valuable for hypertension management using digital technology. The authors have conducted the first comparison study of BPs measured by a recently developed wrist-worn watch-type oscillometric BP monitoring (WBPM) device, the "HeartGuide," versus BPs measured by an ambulatory BP monitoring (ABPM) device, A&D TM-2441, in the office (total of 4 readings alternately measured in the sitting position) and outside the office (30-minutes interval measurements during daytime) in 50 consecutive patients (mean age 66.1 ± 10.8 years). The 2 BP monitoring devices were simultaneously worn on the same non-dominant arm throughout the monitoring period. The mean difference (±SD) in systolic BPs (average of 2 readings) between WBPM and ABPM was 0.8 ± 12.8 mm Hg (P = .564) in the office and 3.2 ± 17.0 mm Hg (P < .001) outside the office. The proportion of differences that were within ±10 mm Hg was 58.7% in the office and 47.2% outside the office. In a mixed-effects model analysis, the temporal trend in the difference between the out-of-office BPs measured by the two devices was not statistically significant. In conclusion, the difference between the WBPM and ABPM device was acceptable both in and out of the office.

Indexed as

Blood Pressure MonitorsHypertensionWearable Electronic DevicesAgedBlood PressureBlood Pressure Monitoring, AmbulatoryHumansMiddle Agedambulatory blood pressurecomparison studyHeartGuidewearable watch-type wrist blood pressure monitoring