Mitral valve flattening and parameter mapping for patient-specific valve diagnosis.

Nils Lichtenberg, Pepe Eulzer, Gabriele Romano, Andreas Brčić, Matthias Karck, Kai Lawonn, Raffaele De Simone, Sandy Engelhardt

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. An ex-vivo and in-vitro dynamic simulator for surgical and transcatheter mitral valve interventions.International journal of computer assisted radiology and surgery · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nils LichtenbergInstitute for Computational Visualistics, University of Koblenz-Landau, Koblenz, Germany. nlichtenberg@uni-koblenz.de.ORCID http://orcid.org/0000-0002-1008-803X
Pepe EulzerInstitute for Computational Visualistics, University of Koblenz-Landau, Koblenz, Germany.
Gabriele RomanoDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Andreas BrčićDepartment of Anaesthesiology, Heidelberg University Hospital, Heidelberg, Germany.
Matthias KarckDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Kai LawonnInstitute for Computer Science, Friedrich-Schiller-University, Jena, Germany.
Raffaele De SimoneDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Sandy EngelhardtWorking Group Artificial Intelligence in Cardiovascular Medicine, University Hospital Heidelberg, Heidelberg, Germany.

Funding

Deutsche Forschungsgemeinschaft DE 2131/2-1Deutsche Forschungsgemeinschaft EN1197/2-1Deutsche Forschungsgesellschaft LA 3855/1-1
6 · The paper itself

Abstract

purposeIntensive planning and analysis from echocardiography are a crucial step before reconstructive surgeries are applied to malfunctioning mitral valves. Volume visualizations of echocardiographic data are often used in clinical routine. However, they lack a clear visualization of the crucial factors for decision making.

methodsWe build upon patient-specific mitral valve surface models segmented from echocardiography that represent the valve's geometry, but suffer from self-occlusions due to complex 3D shape. We transfer these to 2D maps by unfolding their geometry, resulting in a novel 2D representation that maintains anatomical resemblance to the 3D geometry. It can be visualized together with color mappings and presented to physicians to diagnose the pathology in one gaze without the need for further scene interaction. Furthermore, it facilitates the computation of a Pathology Score, which can be used for diagnosis support.

resultsQuality and effectiveness of the proposed methods were evaluated through a user survey conducted with domain experts. We assessed pathology detection accuracy using 3D valve models in comparison with the novel visualizations. Classification accuracy increased by 5.3% across all tested valves and by 10.0% for prolapsed valves. Further, the participants' understanding of the relation between 3D and 2D views was evaluated. The Pathology Score is found to have potential to support discriminating pathologic valves from normal valves.

conclusionsIn summary, our survey shows that pathology detection can be improved in comparison with simple 3D surface visualizations of the mitral valve. The correspondence between the 2D and 3D representations is comprehensible, and color-coded pathophysiological magnitudes further support the clinical assessment.

Indexed as

EchocardiographyEchocardiography, Three-DimensionalFemaleHumansMaleMitral ValveMitral Valve InsufficiencyReproducibility of ResultsMitral valveParamterizationQuantificationVisualization