Evidence map›Paper›PMID 31950389›Full record

ArticleMagma (New York, N.Y.)2020

A 12-channel flexible receiver coil for accelerated tongue imaging.

Luuk Voskuilen, Paul de Heer, Lisette van der Molen, Alfons J M Balm, Ferdinand van der Heijden, Gustav J Strijkers, Ludi E Smeele, Aart J Nederveen

Open access · hybridAbstract read
In one paragraph

Article in Magma (New York, N.Y.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. RF Coil Setup forFrontiers in neurology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Luuk VoskuilenDepartment of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Antoni Van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands. luukvoskuilen@gmail.com.ORCID http://orcid.org/0000-0003-0552-9512
Paul de HeerDepartment of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
Lisette van der MolenDepartment of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Antoni Van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.
Alfons J M BalmDepartment of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Antoni Van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.
Ferdinand van der HeijdenDepartment of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Antoni Van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.
Gustav J StrijkersBiomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
Ludi E SmeeleDepartment of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Antoni Van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.
Aart J NederveenDepartment of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
The Netherlands Cancer Institute · NLAmsterdam University Medical Centers · NLAcademic Center for Dentistry Amsterdam · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveMRI of the tongue requires acceleration to minimise motion artefacts and to facilitate real-time imaging of swallowing. To accelerate tongue MRI, we designed a dedicated flexible receiver coil. MATERIALS AND

methodsWe designed a flexible 12-channel receiver coil for tongue MRI at 3T and compared it to a conventional head-and-neck coil regarding SNR and g-factor. Furthermore, two accelerated imaging techniques were evaluated using both coils: multiband (MB) diffusion-tensor imaging (DTI) and real-time MRI of swallowing.

resultsThe flexible coil had significantly higher SNR in the anterior (2.1 times higher, P = 0.002) and posterior (2.0 times higher, P < 0.001) parts of the tongue, while the g-factor was lower at higher acceleration. Unlike for the flexible coil, the apparent diffusion coefficient (P = 0.001) and fractional anisotropy (P = 0.008) deteriorated significantly while using the conventional coil after accelerating DTI with MB. The image quality of real-time MRI of swallowing was significantly better for hyoid elevation (P = 0.029) using the flexible coil.

conclusionFacilitated by higher SNR and lower g-factor values, our flexible tongue coil allows faster imaging, which was successfully demonstrated in MB DTI and real-time MRI of swallowing.

Indexed as

DeglutitionImage Processing, Computer-AssistedAdultAlgorithmsAnisotropyArtifactsDiffusion Tensor ImagingEquipment DesignFemaleHealthy VolunteersHumansImage EnhancementMagnetic Resonance ImagingMalePhantoms, ImagingSignal-To-Noise RatioAccelerationCineDeglutitionDiffusion tensor imagingMagnetic resonance imagingTongue

Identifiers

PMID31950389
PMCPMC7351800
OpenAlexW2999265349

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.