Evidence map›Paper›PMID 31949476›Full record

ArticleTherapeutic advances in urology

Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties.

Arie Carneiro, Marcelo Langer Wroclawski, Guilherme Andrade Peixoto, Jonathan Doyun Cha, Natasha Kouvaleski Saviano Moran, Felipe Ko Chen, Henrique Nelson Satkunas, José Roberto Augusto Campos, Alides Maria Mendes Rasabone Garcia, Manoj Monga and 1 more

Open access · goldAbstract read
In one paragraph

Article in Therapeutic advances in urology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 4 institutions in 2 countries.

Arie CarneiroDepartment of Urology, Hospital Israelita Albert Einstein, São Paulo, SP - 06455-010, Brazil; Faculdade de Medicina do ABC, São André, Brazil.
Marcelo Langer WroclawskiHospital Israelita Albert Einstein, São Paulo, Brazil; Faculdade de Medicina do ABC, São André, Brazil.
Guilherme Andrade PeixotoFaculdade de Medicina do ABC, São André, Brazil.ORCID https://orcid.org/0000-0002-9022-1880
Jonathan Doyun ChaHospital Israelita Albert Einstein, São Paulo, Brazil.
Natasha Kouvaleski Saviano MoranFaculdade de Medicina do ABC, São André, Brazil.
Felipe Ko ChenFaculdade de Medicina do ABC, São André, Brazil.
Henrique Nelson SatkunasMauá Technology Institute, São Caetano do Sul, Brazil.
José Roberto Augusto CamposMauá Technology Institute, São Caetano do Sul, Brazil.
Alides Maria Mendes Rasabone GarciaHospital Israelita Albert Einstein, São Paulo, Brazil.
Manoj MongaCleveland Clinic, Cleveland, OH, USA.
Gustavo Caserta LemosHospital Israelita Albert Einstein, São Paulo, Brazil.
Hospital Israelita Albert Einstein · BRFaculdade de Medicina do ABC · BRInstituto Mauá de Tecnologia · BRCleveland Clinic · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe three-way indwelling urinary catheter (IUC) is used for continuous bladder irrigation and is considered the cornerstone for clinical treatment of patients with macroscopic hematuria. Although there seems to be a logical relationship between catheter size and efficacy of irrigation and drainage, we often observe relevant variations in these parameters between different brands of catheters available on the market. The aim of this study was to compare the mechanical properties of different models of latex and silicone three-way catheters in an

methodsThree different three-way catheters were evaluated: Gold Silicone-Coated Rusch

resultsDifferent catheter models of the same caliber have different internal irrigation port diameters, internal drainage port diameters and internal cuff port diameters. The Model C IUC internal irrigation port diameter is significantly larger than models A and B. When flows were evaluated, we found that in the same model, the increase in caliber of the IUC was related to an increased drainage flow, but not to an increased irrigation flow.

conclusionPrecise measurements of the internal architecture of the three-way catheter, rather than relying on the caliber itself, could assist surgeons in choosing the best product for each specific patient, while minimizing complications.

Indexed as

hematuriaindwelling cathetersprostatectomytherapeutic irrigationurinary bladder neoplasms

Identifiers

PMID31949476
PMCPMC6952853
OpenAlexW2999310701

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.