Evidence map›Paper›PMID 31944182›Full record

ArticleJMIR rehabilitation and assistive technologies2020

Accuracy and Precision of Three Consumer-Grade Motion Sensors During Overground and Treadmill Walking in People With Parkinson Disease: Cross-Sectional Comparative Study.

Byron Lai, Jeffer E Sasaki, Brenda Jeng, Katie L Cederberg, Marcas M Bamman, Robert W Motl

Open access · goldAbstract read
In one paragraph

Article in JMIR rehabilitation and assistive technologies, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
7.8field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Actionable Wearables Data for the Neurology Clinic: A Proof-of-Concept Tool.Annals of clinical and translational neurology · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. The Use of Consumer Wearable Physical Activity Monitors in Clinical Populations with Functional Limitations.Journal of physical medicine and rehabilitation (Wilmington, Del.) · 2021
    Article
  16. Review
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Byron Lai *Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL, United States.ORCID https://orcid.org/0000-0002-5464-4720
Jeffer E Sasaki *Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL, United States.ORCID https://orcid.org/0000-0002-2083-4104
Brenda Jeng *Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL, United States.ORCID https://orcid.org/0000-0002-4522-1523
Katie L Cederberg *Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL, United States.ORCID https://orcid.org/0000-0001-5693-9293
Marcas M Bamman *UAB Center for Exercise Medicine, University of Alabama at Birmingham, Birmingham, AL, United States.ORCID https://orcid.org/0000-0002-5017-5453
Robert W Motl *Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL, United States.ORCID https://orcid.org/0000-0003-0112-2803
University of Alabama at Birmingham · US

Funding

Rehabilitation Research Resource to Enhance Clinical Trials (ReACT)P2CHD086851 · NICHD · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI BAMMAN, MARCAS M · 2015 to 2019
$7.1M
UAB Pre-Doctoral Training Program in Obesity-Related ResearchT32HL105349 · NHLBI · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI BARBARA A GOWER · 2010 to 2026
$5.7M
NHLBI NIH HHS T32 HL105349NICHD NIH HHS P2C HD086851
6 · The paper itself

Abstract

backgroundWearable motion sensors are gaining popularity for monitoring free-living physical activity among people with Parkinson disease (PD), but more evidence supporting the accuracy and precision of motion sensors for capturing step counts is required in people with PD.

objectiveThis study aimed to examine the accuracy and precision of 3 common consumer-grade motion sensors for measuring actual steps taken during prolonged periods of overground and treadmill walking in people with PD.

methodsA total of 31 ambulatory participants with PD underwent 6-min bouts of overground and treadmill walking at a comfortable speed. Participants wore 3 devices (Garmin Vivosmart 3, Fitbit One, and Fitbit Charge 2 HR), and a single researcher manually counted the actual steps taken. Accuracy and precision were based on absolute and relative metrics, including intraclass correlation coefficients (ICCs) and Bland-Altman plots.

resultsParticipants walked 628 steps over ground based on manual counting, and Garmin Vivosmart, Fitbit One, and Fitbit Charge 2 HR devices had absolute (relative) error values of 6 (6/628, 1.0%), 8 (8/628, 1.3%), and 30 (30/628, 4.8%) steps, respectively. ICC values demonstrated excellent agreement between manually counted steps and steps counted by both Garmin Vivosmart (0.97) and Fitbit One (0.98) but poor agreement for Fitbit Charge 2 HR (0.47). The absolute (relative) precision values for Garmin Vivosmart, Fitbit One, and Fitbit Charge 2 HR were 11.1 (11.1/625, 1.8%), 14.7 (14.7/620, 2.4%), and 74.4 (74.4/598, 12.4%) steps, respectively. ICC confidence intervals demonstrated low variability for Garmin Vivosmart (0.96 to 0.99) and Fitbit One (0.93 to 0.99) but high variability for Fitbit Charge 2 HR (-0.57 to 0.74). The Fitbit One device maintained high accuracy and precision values for treadmill walking, but both Garmin Vivosmart and Fitbit Charge 2 HR (the wrist-worn devices) had worse accuracy and precision for treadmill walking.

conclusionsThe waist-worn sensor (Fitbit One) was accurate and precise in measuring steps with overground and treadmill walking. The wrist-worn sensors were accurate and precise only during overground walking. Similar research should inform the application of these devices in clinical research and practice involving patients with PD.

Indexed as

accelerometerdisabled personsexercisefitness trackerParkinson diseasereproducibilitywearablewearable electronic devices

Identifiers

PMID31944182
PMCPMC6996761
OpenAlexW3000682096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.