Evidence map›Paper›PMID 31942039›Full record

ArticleScientific reports2020

Impact of imaging cross-section on visualization of thyroid microvessels using ultrasound: Pilot study.

Rohit Nayak, Noshin Nawar, Jeremy Webb, Mostafa Fatemi, Azra Alizad

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Rohit NayakDepartment of Radiology, Mayo Clinic College of Medicine and Science, Rochester, Minnesota, 55905, United States.ORCID http://orcid.org/0000-0002-4353-6951
Noshin NawarDepartment of Radiology, Mayo Clinic College of Medicine and Science, Rochester, Minnesota, 55905, United States.
Jeremy WebbDepartment of Radiology, Mayo Clinic College of Medicine and Science, Rochester, Minnesota, 55905, United States.
Mostafa FatemiDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, Minnesota, 55905, United States.ORCID http://orcid.org/0000-0002-6603-9077
Azra AlizadDepartment of Radiology, Mayo Clinic College of Medicine and Science, Rochester, Minnesota, 55905, United States. aza@mayo.edu.ORCID http://orcid.org/0000-0002-7658-1572
Mayo Clinic · US

Funding

Using Label-free Ultrasound Angio-Morphometry Analysis for Improving Ultrasound Specificity in Breast Cancer Detection and Treatment MonitoringR01CA239548 · NCI · MAYO CLINIC ROCHESTER · PI ALIZAD, AZRA, FATEMI, MOSTAFA · 2019 to 2023
$2.9M
Multi-parameter Nonlinear Elasticity Mapping of Breast MassesR01CA195527 · NCI · MAYO CLINIC ROCHESTER · PI ALIZAD, AZRA, FATEMI, MOSTAFA · 2016 to 2020
$2.8M
Classification of breast masses based on visco-elastic propertiesR01CA168575 · NCI · MAYO CLINIC ROCHESTER · PI FATEMI, MOSTAFA, INSANA, MICHAEL F · 2013 to 2018
$2.5M
Viscoelastic Parameters estimation and imaging for Thyroid Nodule differentiationR01EB017213 · NIBIB · MAYO CLINIC ROCHESTER · PI ALIZAD, AZRA, CHEN, SHIGAO · 2014 to 2017
$2.2M
Generalized waveform methods for breast viscoelasticity mappingR01CA174723 · NCI · MAYO CLINIC ROCHESTER · PI FATEMI, MOSTAFA · 2014 to 2018
$1.8M
NCI NIH HHS R01 CA168575NCI NIH HHS R01 CA174723NCI NIH HHS R01 CA195527NCI NIH HHS R01 CA239548NIBIB NIH HHS R01 EB017213
6 · The paper itself

Abstract

Non-invasive, contrast-free microvascular imaging of human thyroids can be potentially beneficial in reducing the large number of benign biopsies of suspicious nodules. However, motion incurred by thyroid due to its proximity to the pulsating carotid artery significantly impacts the visualization of blood flow in small vessels. Singular value based spatiotemporal clutter filtering (SVD-STF) improves the performance of tissue rejection in the presence of motion. However, despite effective clutter filtering, motion in thyroid imaging can impact coherent integration of the Doppler ensemble and degrade the visualization of the underlying vasculature. Recently studies have demonstrated that motion correction using 2D normalized cross-correlation based speckle tracking can address this issue, however, only in-plane motion can be tracked and corrected. Given the natural anatomical orientation of the rigid trachea, thyroid and the pulsating carotid artery, we hypothesize that imaging of thyroid microvessels may be more reliable in the longitudinal view than in the transverse. Specifically, distal presence of rigid trachea can limit out-of-plane motion in the longitudinal view. We tested this hypothesis on 48 acquisitions obtained from 24 thyroid patients having at least one suspicious nodule. In each patient, ultrasound images of the thyroid were acquired in both longitudinal and transverse views. Compounded plane-wave imaging was used to acquire the ultrasound images at high frame-rate, which is important for contrast-free small vessel blood flow imaging. Thyroid motion was tracked using 2D normalized cross-correlation based speckle tracking. Tissue clutter was rejected using singular value decomposition based spatiotemporal clutter filtering. The clutter-filtered Doppler ensemble was motion corrected prior to slow-time power Doppler integration. Signal-to-noise and contrast-to-noise ratios were computed to assess the improvement in quality of the power Doppler images. Out-of-plane motion was detected by estimating normalized ensemble cross-correlation coefficient. The results demonstrated that motion associated with the thyroid due to the carotid artery was primarily in the lateral direction, which could be estimated and corrected using 2D speckle tracking. However, the motion in the transverse view displayed increased speckle decorrelation. The average ensemble cross-correlation coefficient of the thyroid ultrasound images were significantly higher (p < 0.05) in the longitudinal view than in the transverse view. The largest improvement in SNR and CNR of the estimated PD images upon motion correction was observed in the longitudinal view (12.95 ± 3.76 dB and 16.48 ± 4.6 dB) than in the transverse view (3.72 ± 0.894 dB and 6.217 ± 1.689 dB). These preliminary results show that motion encountered by the thyroid due to carotid pulsations can be effectively tracked and corrected in the longitudinal view relative to transverse, which is important for reliably visualizing the underlying blood flow.

Indexed as

FemaleHumansImage Processing, Computer-AssistedMaleMicrovesselsPilot ProjectsSignal Processing, Computer-AssistedThyroid GlandUltrasonography

Identifiers

PMID31942039
PMCPMC6962275
OpenAlexW3000315857

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.