Evidence map›Paper›PMID 31940530›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2020

Synthetic Aperture Focusing for Multi-Covariate Imaging of Sub-Resolution Targets.

Matthew R Morgan, Nick Bottenus, Gregg E Trahey, William F Walker

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Adaptive Models for Multi-Covariate Imaging of Sub-Resolution Targets (MIST).IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
  3. Spatial Coherence in Medical Ultrasound: A Review.Ultrasound in medicine & biology · 2022
    Review
  4. Intrinsic Tradeoffs in Multi-Covariate Imaging of Sub-Resolution Targets.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Matthew R Morgan
Nick Bottenus
Gregg E Trahey
William F Walker

Funding

Coherence-Based Fetal Ultrasonic ImagingR01EB017711 · NIBIB · DUKE UNIVERSITY · PI TRAHEY, GREGG E. · 2014 to 2025
$4.7M
Large aperture and wideband modular ultrasound arrays for the diagnosis of liver cancerR01CA211602 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W, TRAHEY, GREGG E. · 2017 to 2021
$3.3M
NCI NIH HHS R01 CA211602NIBIB NIH HHS R01 EB017711
6 · The paper itself

Abstract

Coherence-based imaging methods suffer from reduced image quality outside the depth of field for focused ultrasound transmissions. Synthetic aperture methods can extend the depth of field by coherently compounding time-delayed echo data from multiple transmit events. Recently, our group has presented the Multi-covariate Imaging of Sub-resolution Targets (MIST), an estimation-based method to image the statistical properties of diffuse targets. MIST has demonstrated improved image quality over conventional delay-and-sum, but like many coherence-based imaging methods, suffers from limited depth of field artifacts. This article applies synthetic aperture focusing to MIST, which is evaluated using focused, plane-wave, and diverging-wave transmit geometries. Synthetic aperture MIST is evaluated in simulation, phantom, and in vivo applications, demonstrating consistent improvements in contrast-to-noise ratio (CNR) over conventional dynamic receive MIST outside the transmit depth of field, with approximately equivalent results between synthetic transmit geometries. In vivo synthetic aperture MIST images demonstrated 16.8 dB and 16.6% improvements in contrast and CNR, respectively, over dynamic receive MIST images, as well as 17.4 dB and 32.3% improvements over synthetic aperture B-Mode. MIST performance is characterized in the space of plane-wave imaging, where the total plane-wave count is reduced through coarse angular sampling or total angular span. Simulation and experimental results indicate wide applicability of MIST to synthetic aperture imaging methods.

Indexed as

ArtifactsComputer SimulationFemaleHumansImage Processing, Computer-AssistedLiverMiddle AgedPhantoms, ImagingSignal-To-Noise RatioUltrasonography

Identifiers

PMID31940530
PMCPMC7337595

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.