Evidence map›Paper›PMID 31940176›Full record

ArticleAnalytical chemistry2020

Facile Improvement of Negative Ion Mode Electrospray Ionization Using Capillary Vibrating Sharp-Edge Spray Ionization.

Chong Li, Kushani Attanayake, Stephen J Valentine, Peng Li

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 41 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Cholesterol impacts the formation of huntingtin/lipid complexes and subsequent aggregation.Protein science : a publication of the Protein Society · 2023
    Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Chong LiC. Eugene Bennett Department of Chemistry , West Virginia University , Morgantown , West Virginia , United States.
Kushani AttanayakeC. Eugene Bennett Department of Chemistry , West Virginia University , Morgantown , West Virginia , United States.
Stephen J ValentineC. Eugene Bennett Department of Chemistry , West Virginia University , Morgantown , West Virginia , United States.ORCID 0000-0003-4360-2928
Peng LiC. Eugene Bennett Department of Chemistry , West Virginia University , Morgantown , West Virginia , United States.ORCID 0000-0002-8332-7142
West Virginia University · US

Funding

Development of VSSI-probe technology for in situ probing biological systems using mass spectrometryR01GM135432 · NIGMS · WEST VIRGINIA UNIVERSITY · PI LI, PENG · 2019 to 2023
$1.7M
Developing IMS-SID/MAD-MS Instrumentation for Characterizing Intrinsically Disordered Protein StructureR01GM114494 · NIGMS · WEST VIRGINIA UNIVERSITY · PI VALENTINE, STEPHEN · 2015 to 2019
$1.4M
NIGMS NIH HHS R01 GM114494NIGMS NIH HHS R01 GM135432
6 · The paper itself

Abstract

Electrospray ionization (ESI) is often affected by corona discharge when spraying 100% aqueous solutions as the voltage that induces discharge can be well below the onset voltage of ESI. As a result, it is especially challenging to perform native mass spectrometry in negative ion mode where 100% aqueous solution is preferred. Here we report a simple instrumentation method to improve the performance of ESI in negative ion mode based on capillary vibrating sharp-edge spray ionization. By attaching a fused silica capillary emitter to a vibrating glass slide, improved signal quality is achieved for various analytes in aqueous solutions over applying ESI alone. Compared to commercial ESI sources using nebulization gas to reduce discharge, 10-100-fold enhancement in signal intensity and 3-10-fold improvement in S/N are achieved for various kinds of molecules including DNA, peptides, proteins, and oligosaccharides. Finally, the new method demonstrates utility for native mass spectrometry analysis of proteins and G-quadruplex DNA. The present method is expected to have great potential to be adopted by the scientific community because of its improved analytical performance, simplicity, and low cost.

Indexed as

DNAG-QuadruplexesProteinsSpectrometry, Mass, Electrospray IonizationDNAProteins

Identifiers

PMID31940176
PMCPMC7318871
OpenAlexW3000429282

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.