Evidence map›Paper›PMID 31939035›Full record

Trial reportLasers in medical science2020

Clinical outcomes of micropulse transscleral cyclophotocoagulation in refractory glaucoma-18 months follow-up.

Maria Alexandra Preda, Olimpiu L Karancsi, Mihnea Munteanu, Horia T Stanca

Abstract readClinical Trial
PubMed Publisher
In one paragraph

Trial report in Lasers in medical science, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed, 1 pooled it
7.9field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed, 1 synthesis or guideline pooled it, 64 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Comparative efficacy and safety of micropulse transscleral laser cyclophotocoagulation using different duration protocols in eyes with good visual acuity.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2021
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Maria Alexandra PredaDepartment of Ophthalmology, "Victor Babes" University of Medicine and Pharmacy, Timisoara, Romania.
Olimpiu L KarancsiDepartment of Oral Implantology and Prosthetic Restorations on Implants, "Victor Babes" University of Medicine and Pharmacy, Timisoara, Romania.
Mihnea MunteanuDepartment of Ophthalmology, "Victor Babes" University of Medicine and Pharmacy, Timisoara, Romania. mihneam1@gmail.com.
Horia T StancaDepartment of Ophthalmology, "Carol Davila" University of Medicine and Pharmacy, Bucharest, Romania.
Victor Babeș University of Medicine and Pharmacy Timișoara · ROCarol Davila University of Medicine and Pharmacy · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study is to evaluate the clinical outcomes of micropulse transscleral cyclophotocoagulation (mTSCPC) in cases of refractory glaucoma. Patients with refractory glaucoma were selected to undergo mTSCPC, using the MP3 handpiece from Iridex Laser Systems. Follow-up examinations occurred on a regular basis for 18 months after the procedure. One hundred eyes of 97 patients were treated. Mean pre-laser intraocular pressure (IOP) was 39.14 ± 13.84 mmHg. This was reduced significantly to 22.77.8 ± 10.48 mmHg (41.82% reduction; p < 0.001) at week 1. At months 1, 3, 6, 12, and 18 the IOP mean was 23.81 ± 9.44, 24.27 ± 9.17, 23.09 ± 8.47, 22.76 ± 8.14, and 22.77 ± 8.13 mmHg. The success rate at 18 months was the highest 90.91% for the group with IOP below 26 mmHg and the lowest 70.00% for the IOP group 26-30 mmHg. The mean number of anti-glaucoma drops decreased from 2.63 ± 0.87 to 1.78 ± 0.95. The number of treatments performed was 1.26. The pain felt during the procedure was reported as being moderate. No major postoperative complications were noted. Micropulse transscleral cyclophotocoagulation is a non-invasive, repeatable laser procedure that offers both good and stable results in lowering IOP and decreases the use of antiglaucoma medications for up to 18 months.

Indexed as

Laser CoagulationAdultAgedAged, 80 and overCiliary BodyFemaleFollow-Up StudiesGlaucomaHumansIntraocular PressureMaleMiddle AgedScleraTreatment OutcomeVisual Analog ScaleYoung AdultDiode laserIntraocular pressureMicropulse transscleral cyclophotocoagulationRefractory glaucoma

Identifiers

PMID31939035
OpenAlexW2998961427

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.