Evidence map›Paper›PMID 31938585›Full record

ArticleCureus2019

Electrical Activity of the Diaphragm in a Small Cohort of Preterm Infants on Noninvasive Neurally Adjusted Ventilatory Assist and Continuous Positive Airway Pressure: A Prospective Comparative Pilot Study.

Arpit Gupta, Rishi Lumba, Sean Bailey, Sourabh Verma, Uday Patil, Pradeep Mally

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 2 pooled it
1.0field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 syntheses or guidelines pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. NIV-NAVA versus non-invasive respiratory support in preterm neonates: a meta-analysis of randomized controlled trials.Journal of perinatology : official journal of the California Perinatal Association · 2024
    Pooled it
  3. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Arpit GuptaNeonatology, Metropolitan Hospital Center, New York, USA.
Rishi LumbaPediatrics/Neonatal Perinatal Medicine, New York University School of Medicine, New York, USA.
Sean BaileyPediatrics, New York University School of Medicine, New York, USA.
Sourabh VermaPediatrics, New York University School of Medicine, New York, USA.
Uday PatilPediatrics/Neonatal Perinatal Medicine, Icahn School of Medicine at Mt. Sinai & New York City H + H / Elmhurst, Elmhurst, USA.
Pradeep MallyPediatrics, New York University School of Medicine, New York, USA.
Perinatal Institute · GBMetropolitan Hospital Center · USNew York University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the electrical activity of the diaphragm (Edi) of premature infants placed on continuous positive airway pressure (CPAP) with the Edi of premature infants placed on noninvasive neurally adjusted ventilatory assist (NIV NAVA). The secondary aim was to evaluate the feasibility of the use of NIV NAVA mode in the busy tertiary neonatal unit. STUDY

designThis was a prospective crossover pilot study of premature infants requiring noninvasive respiratory support. Infants were randomized to initially receive either CPAP/biphasic (group 1) or NIV NAVA (group 2) and were then crossed over to the alternate group. Continuous Edi signals were recorded for 24 h, with 12 h each on CPAP/biphasic, and NIV NAVA along with other clinical and respiratory parameters.  Results: Ten infants with a mean gestation age of 29 weeks (range 25-34 weeks) were enrolled, with a total cumulative Edi monitoring of 240 h. The average Edi peak on the biphasic/CPAP group (15.6 ± 7 mcV) was significantly higher (P < 0.005), compared to the Edi Peak on the NIV NAVA group (10.8 ± 3.3 mcV). The Edi min values were 3.23 ± 1.1 mcV, and 3.07 ± 0.5 mcV on CPAP/biphasic and NIV NAVA (P = 0.69) respectively. There were no significant differences in other clinical parameters between the two groups. No major adverse events were recorded during Edi catheter monitoring.

conclusionThe Edi peak values were significantly lower in NIV NAVA mode compared to CPAP/biphasic mode. The Edi catheter and NIV NAVA may also be used safely in premature infants.

Indexed as

biphasiccpapelectrical activity of the diaphragmneurally adjusted ventilatory assistnoninvasive ventilationpreterm

Identifiers

PMID31938585
PMCPMC6942504
OpenAlexW2991717477

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.