Design and evaluation of a laboratory-based wheelchair castor testing protocol using community data.

Anand Mhatre, Norman Reese, Jon Pearlman

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Wheelchair Servicing for Older Adults: Cross-Sectional Study.JMIR rehabilitation and assistive technologies · 2025
    Article
  2. Article
  3. Article
  4. Rolling resistance of casters increases significantly after two years of simulated use.Journal of rehabilitation and assistive technologies engineering
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Anand MhatreDepartment of Rehabilitation Science and Technology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America.ORCID 0000-0001-6179-3727
Norman ReeseInternational Society of Wheelchair Professionals, Pittsburgh, Pennsylvania, United States of America.
Jon PearlmanDepartment of Rehabilitation Science and Technology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America.
University of Pittsburgh · USLeTourneau University · US

Funding

ACL HHS 90REGE0001
6 · The paper itself

Abstract

Wheelchair castors fail frequently causing physical, social and economic consequences for wheelchair users. These failures occur in spite of established wheelchair test methods and regulations, suggesting that the existing tests may not be sufficient to screen poorly designed castors. An expert stakeholder group, convened by the International Society of Wheelchair Professionals (ISWP), noted castor failures as a high priority and recommended that a new castor testing system should be developed. In a previous study, the effect of shock exposure on castor durability was studied. The current paper extends the previous work and focuses on the development of a castor testing protocol based on shock, corrosion and abrasion exposure data collected in the community. The testing protocol was applied to 8 different castor models tested under four conditions: shock, corrosion + shock, abrasion + shock and abrasion + corrosion + shock. For each model, a total of n = 8 samples were evaluated across the four conditions. Results demonstrate that corrosion and abrasion reduced castor durability between 13% to 100% depending on the model. Importantly, the inclusion of corrosion and abrasion resulted in changes in the failure modes for 75% of the tested models and two-thirds of the altered failure modes are associated with increased risk of injury for wheelchair users. These results suggest that corrosion and abrasion present in the community reduce castor durability, thus supporting their inclusion in the castor testing protocol and potentially other wheelchair standards.

Indexed as

Equipment DesignResidence CharacteristicsWheelchairsDatabases, FactualHumansMaterials Testing