ArticlePloS one2020
Design and evaluation of a laboratory-based wheelchair castor testing protocol using community data.
Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 10 citations in OpenAlex.
- Wheelchair Servicing for Older Adults: Cross-Sectional Study.JMIR rehabilitation and assistive technologies · 2025Article
- Ultralight wheelchair part failures are associated with sensor-monitored road shocks: A pilot study.Assistive technology : the official journal of RESNA · 2025Article
- Community-based wheelchair caster failures call for improvements in quality and increased frequency of preventative maintenance.Spinal cord · 2022Article
- Rolling resistance of casters increases significantly after two years of simulated use.Journal of rehabilitation and assistive technologies engineeringArticle
- Accelerated wear testing shows that thermoplastic bushings could be a cost-effective and durable alternative to traditional bearings for wheelchair caster use.Journal of rehabilitation and assistive technologies engineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
Wheelchair castors fail frequently causing physical, social and economic consequences for wheelchair users. These failures occur in spite of established wheelchair test methods and regulations, suggesting that the existing tests may not be sufficient to screen poorly designed castors. An expert stakeholder group, convened by the International Society of Wheelchair Professionals (ISWP), noted castor failures as a high priority and recommended that a new castor testing system should be developed. In a previous study, the effect of shock exposure on castor durability was studied. The current paper extends the previous work and focuses on the development of a castor testing protocol based on shock, corrosion and abrasion exposure data collected in the community. The testing protocol was applied to 8 different castor models tested under four conditions: shock, corrosion + shock, abrasion + shock and abrasion + corrosion + shock. For each model, a total of n = 8 samples were evaluated across the four conditions. Results demonstrate that corrosion and abrasion reduced castor durability between 13% to 100% depending on the model. Importantly, the inclusion of corrosion and abrasion resulted in changes in the failure modes for 75% of the tested models and two-thirds of the altered failure modes are associated with increased risk of injury for wheelchair users. These results suggest that corrosion and abrasion present in the community reduce castor durability, thus supporting their inclusion in the castor testing protocol and potentially other wheelchair standards.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.