Evidence map›Paper›PMID 31922083›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2020

Effect of CZT system characteristics on Compton scatter event recovery.

Sheng Yang, Mohan Li, Michael Reed, James Hugg, Henry Chen, Shiva Abbaszadeh

Open access · hybridAbstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Back-end readout electronic design and initial results: a head-and-neck dedicated PET system based on CZT.Proceedings of SPIE--the International Society for Optical Engineering · 2021
    Article
  5. Design study of a dedicated head and neck cancer PET system.IEEE transactions on radiation and plasma medical sciences · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Sheng YangDepartment of Nuclear, Plasma, and Radiological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801 USA.
Mohan LiDepartment of Nuclear, Plasma, and Radiological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801 USA.
Michael ReedKromek USA/eV Products, Saxonburg, PA, 16056, USA.
James HuggKromek USA/eV Products, Saxonburg, PA, 16056, USA.
Henry ChenKromek USA/eV Products, Saxonburg, PA, 16056, USA.
Shiva AbbaszadehDepartment of Nuclear, Plasma, and Radiological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801 USA.
Kromek (United States) · USUniversity of Illinois Urbana-Champaign · US

Funding

High spatial resolution dedicated head and neck PET system based on cadmium zinc telluride detectorsR01EB028091 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI ABBASZADEH, SHIVA · 2018 to 2021
$2.6M
NIBIB NIH HHS R01 EB028091
6 · The paper itself

Abstract

Improving 511 keV photon detection sensitivity is a common goal for positron emission tomography system designers. One attractive approach to increase sensitivity is recovering events that are normally rejected. The kinematics of Compton scattering can be used to recover the line of response through direction difference angle (DDA). The uncertainty of DDA is determined by the energy and spatial resolution of a system. In this work, we evaluated the performance of small animal CZT-based positron emission tomography systems with energy resolution of 1%, 4%, and 6% and different spatial resolution based on prior work for guiding new design efforts. Designs with energy resolution limited by counting statistics and by electronic noise were considered. The influence of modifying the conventional energy window and uncertainty of DDA was investigated. For a system with 4% energy resolution and limited by electronic noise, the figure of merit of noise equivalent count increases by 65% as the lower energy bound increases from 471 keV to 493 keV. If the system-wide energy resolution becomes worse than 4% of the full width half maximum at 511 keV, going to a pixel size finer than 1 mm has very limited effect in reducing total angular uncertainty. For a system with 1% energy resolution, as the spatial resolution improves from 1 mm to 0.5 mm, the contrast-to-noise ratio increases by 9%.

Indexed as

Compton RecoveryCZTPETSensitivity

Identifiers

PMID31922083
PMCPMC6952068
OpenAlexW2943939041

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.