ArticleUpdates in surgery2020
Safety and efficacy of prophylactic resorbable biosynthetic mesh in loop-ileostomy reversal: a case-control study.
Article in Updates in surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 5 syntheses or guidelines pooled it, 13 citations in OpenAlex.
- Type of mesh and wall plane in prophylactic mesh after stoma closure: A network meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2025Pooled it
- Reversal of stoma with biosynthetic mesh fascial reinforcement: a systematic review and meta-analysis.Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland · 2024Pooled it
- An evidence map and synthesis review with meta-analysis on the risk of incisional hernia in colorectal surgery with standard closure.Hernia : the journal of hernias and abdominal wall surgery · 2022Pooled it
- Prevention of incisional hernia at the site of stoma closure with different reinforcing mesh types: a systematic review and meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2021Pooled it
- Closure of stoma site with or without prophylactic mesh reinforcement: a systematic review and meta-analysis.International journal of colorectal disease · 2020Pooled it
- Composition and influencing factors of hospitalization costs in adult patients undergoing incisional hernia repair surgery.Updates in surgery · 2026Article
- Article
- Prevention of incisional hernia with biosynthetic mesh at the site of temporary ileostomy closure (PRINCESS Study): Preliminary Results.Hernia : the journal of hernias and abdominal wall surgery · 2025Observational
- Long-term outcome of prophylactic biosynthetic mesh reinforcement at the time of loop ileostomy reversal for colorectal cancer- results of a case-matched study.Hernia : the journal of hernias and abdominal wall surgery · 2025Article
- Prophylactic Biosynthetic Retrorectus Mesh Placement During Stoma Reversal Reduces the Rate of Stoma Site Incisional Hernia.The Permanente journal · 2024Observational
- Two-meshes approach in posterior component separation with transversus abdominis release: the IMPACT study (Italian Multicentric Posterior-separation Abdominal Complex hernia Transversus-release).Hernia : the journal of hernias and abdominal wall surgery · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Loop ileostomy (LI) is a widely used temporary stoma technique. Reversal of LI is generally considered a minor and safe procedure, with very low short-term postoperative mortality and morbidity rates. Complications include incisional hernia (IH), carrying a high probability of surgical repair. Clinical measures to reduce the IH rate warrant consideration. Recent researches suggest the use of a prophylactic non-absorbable mesh to reduce IH rate; however, surgeons are reluctant to implant a permanent foreign material in contaminated operative fields, because of a higher risk of mesh-related complications, infection, seroma, and pain. The aim of the present study is to assess feasibility, potential benefits, and safety of a prophylactic biosynthetic mesh placed during LI reversal. From January 2016 to December 2018, 26 consecutive patients underwent LI reversal positioning a resorbable biosynthetic mesh in an on-lay position [mesh group (MG)]. The mesh used was a GORE BIO-A tissue reinforcement, a biosynthetic mesh composed of a bioabsorbable polyglycolide-trimethylene carbonate copolymer. The MG was matched with 58 patients [control group (CG)], undergoing LI reversal without mesh placement from January 2013 to December 2018. To detect IH, abdominal wall was studied according to clinical and ultrasonographic criteria. Primary endpoint was IH rate on LI site, at 6 and 12 months after stomal reversal. Secondary endpoints included incidence of wound events. Thirty-day morbidity was classified according to Clavien-Dindo score; mortality and length of hospital stay were also collected. Mean follow-up was 15.4 ± 2.3 months (range 12.4-22.0) for MG vs 37.2 ± 26.9 (range 24.9-49.7) for. CG. At 1 year of follow-up, IH rate was lower in MG (n = 1/26 [3.8%]) vs CG (n = 19/58 [32.7%]; P < 0.05). A clinically evident IH was less frequent in MG (n = 0 [0%]) vs CG (n = 13 [68%]; P < 0.05). A radiologic IH was less frequent in MG (n = 1 [3%]) vs CG (n = 6 [31%]; P < 0.05). Stoma site hernia was repaired in 9/19 patients (47%) in CG; no patient of MG has hernia repaired. Incarcerated IH was observed in one patient of CG. No postoperative mortality was reported. Overall postoperative morbidity showed no difference comparing MG and MG (n = 5 [17%] vs n = 15 [19%], respectively; P > 0.05). Surgical site infections (SSI) were treated with antibiotic therapy, no debridement was necessary. Seroma occurred in two patients, one for each group. No statistically significant difference for surgical outcomes was found between the two groups at 30 days. Early results of the present study suggest that an on-lay prophylactic placement of GORE BIO-A tissue reinforcement might lower IH rate at LI site. The procedure seems to be safe and effective, even long-term results and further studies are needed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.