ArticleThe journal of extra-corporeal technology2019
Does Standardizing Extracorporeal Circuit Design for Cardiopulmonary Bypass Affect Outcomes? Results from a National Perfusion Registry.
Article in The journal of extra-corporeal technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- The Effect of Antifibrinolytic Use on Intraoperative Cell Salvage: Results from a National Registry of Surgical Procedures.The journal of extra-corporeal technology · 2020Article
- Publication Ethics.The journal of extra-corporeal technology · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Standardization of clinical practice is an effective means of reducing unwanted variation and improving safety. There are numerous extracorporeal circuit (ECC) designs in clinical practice which both complicates the conduct of cardiopulmonary bypass (CPB) and increases costs, especially in situations where clinicians may conduct perfusion at more than one center. The current study was undertaken to determine the effect of standardizing ECCs by incorporating new generation devices as part of a pack enhancement project (PEP). Standardization of ECCs in cardiac centers within a national perfusion provider was undertaken to incorporate new generation oxygenators to reduce variation and improve safety among clinicians. The PEP was carried out in adult centers performing cardiac surgery across America. Data were analyzed for 12 months before the change and compared with those of an equal time thereafter. The outcome measures were ECC prime volume, hematocrit (HCT) drift, and transfusion of intraoperative red blood cells (RBCs). The transition time frame took just less than 12 months and included soliciting input from end-users, pack redesign, and education and implementation. Before the PEP, 91 hospitals used 47 different ECC configurations, which was reduced by 83.0% to eight packs. Regression analysis comparing outcomes between PEP and non-PEP patients showed statistically significant but subtle changes. The net prime volume increased slightly in the PEP group (733-750 mL,
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.