Evidence map›Paper›PMID 31908938›Full record

ArticleJournal of orthopaedic translation2020

Does mobile-bearing have better flexion and axial rotation than fixed-bearing in total knee arthroplasty? A randomised controlled study based on gait.

Yi-Ming Zeng, Meng-Ning Yan, Hui-Wu Li, Jun Zhang, You Wang

Abstract read
In one paragraph

Article in Journal of orthopaedic translation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. No difference between mobile and fixed bearing in primary total knee arthroplasty: a meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022
    Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yi-Ming ZengShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopedic Surgery, Shanghai Ninth's People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, PR China.
Meng-Ning YanShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopedic Surgery, Shanghai Ninth's People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, PR China.
Hui-Wu LiShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopedic Surgery, Shanghai Ninth's People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, PR China.
Jun ZhangShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopedic Surgery, Shanghai Ninth's People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, PR China.
You WangShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopedic Surgery, Shanghai Ninth's People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, PR China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo analyse the 6 degrees of freedom of the knee and gait data of patients with medial knee osteoarthritis before and after fixed-bearing (FB) and mobile-bearing (MB) total knee arthroplasty (TKA) ​and examine the influence of TKA on gait characteristics and the difference between FB and MB prosthesis. We also sought to explore the prosthesis options available for TKA in these patients.

methodsThirty patients who underwent TKA at the Department of Orthopedics at our hospital from June to October 2017 were included. All patients had a lower limb mechanical axis (hip-knee-ankle angle) of less than 180° which were regarded as genu varum knees and had medial knee osteoarthritis. Patients were randomised divided into the FB group ​and the MB group according to the knee prosthesis implanted. An infrared navigation three-dimensional portable knee motion analysis system (Opti-Knee®, Shanghai Innomotion, Inc.) was used to acquire data on the 6 degrees of freedom of both knees when walking on flat ground before and after surgery (angle of tibia relative to femur parameters: flexion-extension, internal rotation-external rotation, abduction-adduction; displacement parameters: anterior-posterior, proximal-distal, medial-lateral). Postoperative follow-up efficacy was assessed using the Oxford Knee Score system.

resultsThere were significant differences in the maximum values of the internal/external rotation and flexion/extension angle between patients post-TKA and the healthy population,

conclusionsTKA can make the parameters of knee gait characteristics closer to the normal population. Medial knee osteoarthritis patients who received a MB prosthesis in TKA had better joint flexion function and axial rotation than the FB one. However, there is insufficient evidence to suggest that the MB prosthesis is a better option for patients with medial knee osteoarthritis. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: To date, no consensus for prosthesis selection in TKA has been established. This study found significant differences in joint flexion/extension angle and internal/external rotation during gait post-TKA surgery in medial knee osteoarthritis patients who received different prostheses. This will provide some references for prosthesis selection for a large number of genu varum patients in clinical practice.

Indexed as

Fixed-bearingGait analysisKinematicMobile-bearingProsthesis implantationTotal knee arthroplasty

Identifiers

PMID31908938
PMCPMC6939107

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.