ArticleJournal of orthopaedic translation2020
Design of a new magnesium-based anterior cruciate ligament interference screw using finite element analysis.
Article in Journal of orthopaedic translation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Material synthesis and design optimization of biomaterials for biomedical implant applications.BioImpacts : BI · 2025Review
- Mechanobiomaterials: Harnessing mechanobiology principles for tissue repair and regeneration.Mechanobiology in medicine · 2024Review
- In Vitro Investigation of the Fixation Performance of a Bioabsorbable Magnesium ACL Interference Screw Compared to a Conventional Interference Screw.Life (Basel, Switzerland) · 2023Article
- Magnesium-based alloys with adapted interfaces for bone implants and tissue engineering.Regenerative biomaterials · 2023Review
- Development of degradable magnesium-based metal implants and their function in promoting bone metabolism (A review).Journal of orthopaedic translation · 2022Review
- Current strategies for enhancement of the bioactivity of artificial ligaments: A mini-review.Journal of orthopaedic translation · 2022Review
- Rotator cuff repair with biodegradable high-purity magnesium suture anchor in sheep model.Journal of orthopaedic translation · 2022Article
- Clinical translation and challenges of biodegradable magnesium-based interference screws in ACL reconstruction.Bioactive materials · 2021Review
- Tibial cutting guide (resector) holding pins position and subsequent risks of periprosthetic fracture in unicompartmental knee arthroplasty: a finite element analysis study.Journal of orthopaedic surgery and research · 2021Article
- Translation of engineering to medicine: A focus on finite element analysis.Journal of orthopaedic translation · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
BACKGROUND/
objectiveIn anterior cruciate ligament reconstruction, a tendon graft, anchored by interference screws (IFSs), is frequently used as a replacement for the damaged ligament. Generally, IFSs are classified as being either metallic or polymeric. Metallic screws have sharp threads that lacerate the graft, preventing solid fixation. These constructs are difficult to image and can limit bone--screw integration because of the higher stiffness of the screw. Polymeric materials are often a better match to bone's material properties, but lack the strength needed to hold grafts in place. Magnesium (Mg) is a material of great promise for orthopaedic applications. Mg has mechanical properties similar to bone, ability to be seen on magnetic resonance imagings, and promotes bone healing. However, questions still remain regarding the strength of Mg-based screws. Previous
methodsUsing finite element analysis, a comparison study of six drive designs (hexagonal, quadrangle, torx, trigonal, trilobe, and turbine) was performed. This was followed by a parametric analysis to determine appropriate drive depth and drive width.
resultsIt was observed that with a typical torque (2 Nm) used for screw insertion during anterior cruciate ligament reconstruction, the maximum von Mises and shear stress values were concentrated in the corners or turns of the drive, which could lead to stripping if the values were greater than the yield stress of Mg (193 MPa). With a four-time increase in drive depth to be fully driven and a 30% greater drive width, these maximum stress values were significantly decreased by more than 75%.
conclusionIt was concluded that improving the design of a Mg-based screw may increase surgical success rates, by decreasing device failure at insertion. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The results of this work have the potential to improve designs of degradable IFSs, allowing for greater torque to be applied and thus greater screw fixation between host bone and the graft. Such a fixation will allow greater integration, better patient healing, and ultimately improved patient outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials