ArticleJournal of medical physics
4π Radiotherapy Using a Linear Accelerator: A Misnomer in Violation of the Solid Geometric Boundary Conditions in Three-Dimensional Euclidean Space.
Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- CyberKnife in Pediatric Oncology: A Narrative Review of Treatment Approaches and Outcomes.Current oncology (Toronto, Ont.) · 2025Review
- A comparative dose-escalation analysis for reirradiated cancer patients with and without appropriate dose mapping.Radiation and environmental biophysics · 2024Article
- In regards to Pokhrel et al. Clinical validation of ring-mounted halcyon linac for lung SBRT: Comparison to SBRT-dedicated C-arm linac treatments. JACMP 2021 Jan;22(1):261-70.Journal of applied clinical medical physics · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe concept of 4π MATERIALS AND
methodsA surface integral-based mathematical derivation for the maximum achievable solid angle for a linear accelerator was carried out respecting the rotational boundary conditions for gantry and couch in three-dimensional Euclidean space. The allowed movements include a gantry rotation of 0-2π
resultsTotal achievable solid angle by cantilever-type linear accelerator (or any teletherapy machine employing a cantilever design) is , which is applicable only for the foot and brain radiotherapy where the allowed table rotation is 90°-0°-270°. For other sites such as pelvis, thorax, or abdomen, achievable solid angle as the couch rotation comes down significantly. Practically, only suitable couch angle is 0° by avoiding gantry-couch-patient collision.
conclusionsPresent cantilever design of linear accelerator prevents achieving a 4π radian solid angle at any point in the patient. Even the most modern therapy machines like CyberKnife which has a robotic arm also cannot achieve 4π geometry. Maximum achievable solid angle under the highest allowable boundary condition(s) cannot exceed 2π
Indexed as
Identifiers
What OpenQuestion holds
Registered trials