Evidence map›Paper›PMID 31906614›Full record

ArticleAsian spine journal2020

Correlation between the Computed Tomography Values of the Screw Path and Pedicle Screw Pullout Strength: An Experimental Study in Porcine Vertebrae.

Atsushi Ikeura, Taketoshi Kushida, Kenichi Oe, Yoshihisa Kotani, Muneharu Ando, Takashi Adachi, Takanori Saito

Open access · diamondAbstract read
In one paragraph

Article in Asian spine journal, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Atsushi IkeuraDepartment of Orthopaedic Surgery, Kansai Medical University, Hirakata, Japan.
Taketoshi KushidaDepartment of Orthopaedic Surgery, Kansai Medical University, Hirakata, Japan.
Kenichi OeDepartment of Orthopaedic Surgery, Kansai Medical University, Hirakata, Japan.
Yoshihisa KotaniDepartment of Orthopaedic Surgery, Kansai Medical University Medical Center, Moriguchi, Japan.
Muneharu AndoDepartment of Orthopaedic Surgery, Kansai Medical University, Hirakata, Japan.
Takashi AdachiDepartment of Orthopaedic Surgery, Kansai Medical University, Hirakata, Japan.
Takanori SaitoDepartment of Orthopaedic Surgery, Kansai Medical University, Hirakata, Japan.
Kansai Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designBiomechanical study. PURPOSE: To assess the correlation between the computed tomography (CT) values of the pedicle screw path and screw pull-out strength. OVERVIEW OF LITERATURE: The correlation between pedicle screw pull-out strength and bone mineral density has been well established. In addition, several reports have demonstrated a correlation between bone mineral density and CT values. However, no previous biomechanical studies investigated the correlation between CT values and pedicle screw pull-out strength.

methodsSixty fresh-frozen lumbar vertebrae from 6-month-old pigs were used. Before screw insertion, the CT values of the screw path were obtained for each sample. Specimens were then randomly divided into three equal groups. Each group had one of three pedicle screws inserted: 4.0-mm LEGACY (4.0-LEG), 4.5-mm LEGACY (4.5-LEG), or 4.5-mm SOLERA (4.5-SOL) (all from Medtronic Sofamor Danek Inc., Memphis, TN, USA). Each screw had a consistent 30-mm thread length. Axial pull-out testing was performed at a rate of 1.0 mm/min. Correlations between the CT values and pedicle screw pull-out strength were evaluated using Pearson's correlation coefficient analysis.

resultsThe correlation coefficients between the CT values of the screw path and pedicle screw pull-out strength for the 4.0-LEG, 4.5-LEG, and 4.5-SOL groups were 0.836 (p <0.001), 0.780 (p <0.001), and 0.873 (p <0.001), respectively. Greater CT values were associated with greater screw pull-out strength.

conclusionsThe CT values of the screw path were strongly positively correlated with pedicle screw pull-out strength, regardless of the screw type and diameter, suggesting that the CT values could be clinically useful for predicting pedicle screw pull-out strength.

Indexed as

Computed tomographyLumbar vertebraePedicle screwsPigProsthesis failure