Evidence map›Paper›PMID 31905779›Full record

ArticleSensors (Basel, Switzerland)2019

Noise Optimization Design of Frequency-Domain Air-Core Sensor Based on Capacitor Tuning Technology.

Shengbao Yu, Yiming Wei, Jialin Zhang, Shilong Wang

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Shengbao YuCollege of Instrumentation & Electrical Engineering, Jilin University, Changchun 130061, China.
Yiming WeiCollege of Instrumentation & Electrical Engineering, Jilin University, Changchun 130061, China.
Jialin ZhangCollege of Instrumentation & Electrical Engineering, Jilin University, Changchun 130061, China.
Shilong WangCollege of Instrumentation & Electrical Engineering, Jilin University, Changchun 130061, China.
Jilin University · CN

Funding

Department of Science and Technology of Jilin Province 20160204034GX
6 · The paper itself

Abstract

In the semi-aviation frequency-domain electromagnetic measurement, the induction air-core coil and the differential pre-amplifier circuit introduce noise, which affects the sensor and results in receiving weak signals and improving the signal-to-noise ratio of the system. In response to this problem, by analyzing the physical structure of the air-core coil sensor and the mechanism of the amplification circuit, combined with the simulation and experimental tests of voltage noise, current noise, resistance noise and other noise components, analyzed that the thermal noise is the main component of the sensor noise in the system frequency band, but directly removing the matching resistor increases the instability of the circuit, causes the coil to work in an underdamped state, and generates a time domain oscillation at the resonant frequency, source impedance analysis and analysis of differential pre-amplifier circuit in the frequency-domain detection method, abandoning the matching resistance scheme and magnetic flux negative feedback scheme. The matching capacitor is added to make the receiver detect the frequency range in the 1-10 kHz range. In normal operation, the noise level reaches 10 nV level, which not only increases the stability of the circuit, but also reduces the noise of the sensor. It has far-reaching significance for the detection of weak frequency signals.

Indexed as

amplification circuitcoil sensorfrequency-domain electromagnetic methodlow noise

Identifiers

PMID31905779
PMCPMC6982760
OpenAlexW2997901274

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked