Evidence map›Paper›PMID 31903280›Full record

ArticleJournal of thoracic disease2019

Pleural fluid glucose testing using a finger stick glucometer: a novel bedside test.

Tony F Abdo, Himanshu Bhardwaj, Muhammad K Ishaq, Jean I Keddissi, Houssein A Youness

Open access · diamondAbstract read
In one paragraph

Article in Journal of thoracic disease, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Tony F AbdoInterventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, Oklahoma City VA Health Care System and University of Oklahoma Health Sciences Center, Oklahoma, USA.
Himanshu BhardwajInterventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, Oklahoma City VA Health Care System and University of Oklahoma Health Sciences Center, Oklahoma, USA.
Muhammad K IshaqInterventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, Oklahoma City VA Health Care System and University of Oklahoma Health Sciences Center, Oklahoma, USA.
Jean I KeddissiInterventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, Oklahoma City VA Health Care System and University of Oklahoma Health Sciences Center, Oklahoma, USA.
Houssein A YounessInterventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, Oklahoma City VA Health Care System and University of Oklahoma Health Sciences Center, Oklahoma, USA.
Oklahoma City VA Health Care System · USUniversity of Oklahoma Health Sciences Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPleural fluid glucose (PFG) has diagnostic and therapeutic implications for the management of pleural effusion. The literature examining point-of-care testing of PFG is limited, and no studies exist for the bedside measurement of PFG using a glucometer (B-PFG). In this study, we compared the accuracy of B-PFG measurement to standard in-lab measurement (Lab-PFG).

methodsPatients undergoing thoracentesis or thoracostomy were enrolled. PFG was measured at the bedside with a finger stick blood glucometer (ACCU-CHEK

resultsSixty patients were included. Mean age was 64.1 years. Forty-nine patients had exudative effusions (41% malignant, 26% parapneumonic, and 33% others). There was a significant correlation between the B-PFG and the Lab-PFG (r=0.98, 95% CI of 0.97 to 0.99; P<0.0001). There was good agreement between the B-PFG and the Lab-PFG with a mean difference of 14.8 mg/dL [95% limit of agreement (LOA) of -2.2 to 31.8 mg/dL]. This agreement was even better at glucose values less than 80 mg/dL.

conclusionsPFG measured at the bedside with a glucometer closely correlates with the laboratory measurement. Further studies are needed prior to incorporating this test in clinical practice.

Indexed as

glucometerPleural effusionpleural fluid glucose (PFG)thoracentesis

Identifiers

PMID31903280
PMCPMC6940255
OpenAlexW2974624187

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.