Evidence map›Paper›PMID 31902094›Full record

Observational studyJournal of clinical monitoring and computing2020

Perioperative measurement of core body temperature using an unobtrusive passive heat flow sensor.

Louis Atallah, Calina Ciuhu, Igor Paulussen, Edwin Bongers, Antoon H M Blom, Akram Idrissi, Gerrit Noordergraaf

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Journal of clinical monitoring and computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Louis AtallahPatient Care and Measurements Department, Philips Research Eindhoven, High Tech Campus 34, 5656 AE, Eindhoven, The Netherlands. louis.atallah@philips.com.ORCID http://orcid.org/0000-0002-6657-319X
Calina CiuhuPatient Care and Measurements Department, Philips Research Eindhoven, High Tech Campus 34, 5656 AE, Eindhoven, The Netherlands.
Igor PaulussenPatient Care and Measurements Department, Philips Research Eindhoven, High Tech Campus 34, 5656 AE, Eindhoven, The Netherlands.
Edwin BongersPatient Care and Measurements Department, Philips Research Eindhoven, High Tech Campus 34, 5656 AE, Eindhoven, The Netherlands.
Antoon H M BlomDepartment of Fertility, Pregnancy and Parenting Department, Philips Research Eindhoven, High Tech Campus 34, 5656 AE, Eindhoven, The Netherlands.
Akram IdrissiPatient Care and Measurements Department, Philips Research Eindhoven, High Tech Campus 34, 5656 AE, Eindhoven, The Netherlands.
Gerrit NoordergraafDepartment of Anesthesiology, Resuscitation & Pain Management, Elisabeth-Tweesteden Hospital, Tilburg, Hilvarenbeekseweg 60, 5022 GC, Tilburg, The Netherlands.

Funding

Philips Philips Research
6 · The paper itself

Abstract

Clinicians strive to maintain normothermia, which requires measurement of core-body temperature and may necessitate active warming of patients. Monitoring temperature currently requires invasive probes. This work investigates a novel foam-based flexible sensor worn behind the ear for the measurement of core body temperature. This observational study uses the device prototype and clinical data to compare three methods for calculating the temperature from this sensor: a basic heat-flow model, a new dynamic model that addresses changing surrounding temperatures and one that combines the dynamic model with a correction for adhesive quality. Clinical validation was performed with 21 surgical patients (average length of surgery 4.4 h) using an esophageal temperature probe as reference. The operative period was divided into four segments: normal periods (with stable surrounding temperatures), surrounding temperatures increasing due to the use of the Bair Hugger™, stable periods during Bair Hugger™ use and surrounding temperatures decreasing due to its removal. The error bias and limits of agreement over these segments were on average of - 0.05 ± 0.28 °C (95% limits of agreement) overall. The dynamic model outperformed the simple heat-flow model for periods of surrounding temperature changes (12.7% of total time) while it had a similar, high, performance for the temperature-stable periods. The results suggest that our proposed topical sensor can replace invasive core temp sensors and provide a means of consistently measuring core body temperature despite surrounding temperature shifts.

Indexed as

Body TemperatureHot TemperatureEsophagusHumansTemperatureCore body temperatureDynamic modelsUnobtrusive sensorsWearables

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.