Dose and blending fraction quantification for adaptive statistical iterative reconstruction based on low-contrast detectability in abdomen CT.

Yifang Zhou

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author at 1 institution in 1 country.

Yifang ZhouDepartment of Imaging, Imaging Physics Division, S. Mark Taper Foundation Imaging Center, Cedars-Sinai Medical Center, 8700 Beverly Blvd., Los Angeles, California, 90048, USA.
S. Mark Taper Foundation · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe utilization of iterative reconstruction makes it difficult to identify the dose-noise relationship, resulting in empirical design of scan protocols and inconsistent conclusions on dose reduction for consistent image quality. This study was to quantitatively determine the dose and the blending fraction of adaptive statistical iterative reconstruction (ASIR) based on the specified low-contrast detectability (LCD).

methodsA tissue equivalent abdomen phantom and a GE discovery 750 HD computed tomography (CT) were utilized. The normality of the noise distribution was tested at various spatial scales (2.1-9.8 mm) in the presence of ASIR (10-100%) with a wide range of doses (2.24-38 mGy). The statically defined minimum detectable contrast (MDC) was used as the image quality metric. The parametric model decomposed the MDC into two terms: one with and the other without ASIR, each was related to the dose in the form of power law with factors and indices dependent on spatial scales. The parameters were identified by least-square fitting to the experimental data. By considering the constraint of the blending fraction in the range of [0, 1], the dose and ASIR blending fraction were determined for any specified low-contrast detectability (LCD), quantified by the MDC at the concerned lesion size.

resultsIt was verified that noise distribution is normal in the presence of ASIR. It was also found that the noises obtained from the subtractions of adjacent slices had an underestimate of 20% as compared to the ground truth noises, regardless of the spatial scale, pitch, or ASIR blending fraction. The least-square fitting for the parametric model resulted in correlation coefficients from 0.905 to 0.996. The root-mean-square errors ranged from 1.27% to 7.15%.

conclusionThe parametric model can be used to form a look-up-table for dose and ASIR blending fraction. The dose choices may be substantially limited in some cases depending on the required LCD.

Indexed as

Radiography, AbdominalTomography, X-Ray ComputedAlgorithmsContrast MediaHumansImage Processing, Computer-AssistedLeast-Squares AnalysisPhantoms, ImagingRadiation DosageRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsSignal-To-Noise RatioContrast Mediaadaptive statistical iterative reconstructiondose reductionlesion sizeminimum detectable contrastnoise correlation

Identifiers

PMID31898865
PMCPMC7021010
OpenAlexW2998527244

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.