Evidence map›Paper›PMID 31894429›Full record

ArticleJournal of medical ultrasonics (2001)2020

Modified high-resolution wavenumber analysis for detection of pulse wave velocity using coefficient of variation of arterial wall acceleration waveforms.

Ryo Nagaoka, Hideyuki Hasegawa

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical ultrasonics (2001), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ryo NagaokaGraduate School of Science and Engineering for Research, University of Toyama, 3190 Gofuku, Toyama, 930-8555, Japan. nryo@eng.u-toyama.ac.jp.ORCID http://orcid.org/0000-0002-6713-8106
Hideyuki HasegawaGraduate School of Science and Engineering for Research, University of Toyama, 3190 Gofuku, Toyama, 930-8555, Japan.

Funding

Kaken JSPS 18K18395
6 · The paper itself

Abstract

purposeIn high-resolution wavenumber analysis for detection of pulse wave velocity (PWV), phase information of analytic signals is used to estimate the wavenumber. However, the phase information could be affected by the adjacent signals in the temporal direction. Therefore, we propose a modified high-resolution wavenumber analysis technique using real acceleration waveforms of the arterial wall.

methodIn the modified wavenumber analysis, we propose a new evaluation function that corresponds to the inverse of the squared coefficient of variation. The accuracy of estimation of PWV was investigated by performing simulations, and the feasibility was also examined in an in vivo experiment.

resultsIn the simulation experiments, the estimation accuracy using the proposed method was comparable to that using the previous method using phase information. However, when the pulse wave included the reflection components, the PWV estimated using the proposed method was more stable than that estimated using the previous method. Also, in the in vivo experiments, at opening of the aortic valve, the velocity estimated by the proposed method was almost equal to that estimated by the previous method (previous: 2.97 ± 1.2 m/s, proposed: 4.82 ± 1.4 m/s). Meanwhile, when the reflection components were present, the estimated PWV values yielded by the previous and proposed methods were - 1.13 and - 3.50 ± 0.9 m/s, respectively. The PWVs at those two time points estimated by the previous method were quite different, and the PWV estimate was considered to be more affected by the reflected waves.

conclusionThe results of the simulations and in vivo experiments indicated that the modified high-resolution wavenumber analysis method was less affected by the reflected waves and more accurate in estimation of PWVs of both the forward and reflected waves.

Indexed as

Blood Flow VelocityCarotid Artery, CommonComputer SimulationHumansImage Processing, Computer-AssistedMaleMiddle AgedPulse Wave AnalysisReference ValuesReproducibility of ResultsUltrasonographyPhasePulse wave velocityReal part of complex signalsWavenumber analysis

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.