Evidence map›Paper›PMID 31893849›Full record

ArticleThe Review of scientific instruments2019

A transition-edge sensor-based x-ray spectrometer for the study of highly charged ions at the National Institute of Standards and Technology electron beam ion trap.

P Szypryt, G C O'Neil, E Takacs, J N Tan, S W Buechele, A S Naing, D A Bennett, W B Doriese, M Durkin, J W Fowler and 8 more

Abstract read
In one paragraph

Article in The Review of scientific instruments, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. A Study of the Position-Dependent Response of Thermal Kinetic Inductance Detectors Through the Use of Cryogenic Beam Steering.IEEE transactions on applied superconductivity : a publication of the IEEE Superconductivity Committee · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. The NIST Vacuum Double-Crystal Spectrometer: A Tool for SI-Traceable Measurement of X-Ray Emission Spectra.Journal of research of the National Institute of Standards and Technology · 2021
    Article
  8. Dielectronic resonances ofPhysical review. A · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

P SzyprytQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.ORCID 0000000201843419
G C O'NeilQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.ORCID 0000000334502263
E TakacsQuantum Measurement Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.
J N TanQuantum Measurement Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.
S W BuecheleQuantum Measurement Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.
A S NaingQuantum Measurement Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.
D A BennettQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.ORCID 0000000330113690
W B DorieseQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.ORCID 0000000311076441
M DurkinQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.
J W FowlerQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.
J D GardDepartment of Physics, University of Colorado, Boulder, Colorado 80309, USA.ORCID 0000000341959544
G C HiltonQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.
K M MorganQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.ORCID 0000000265971030
C D ReintsemaQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.
D R SchmidtQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.
D S SwetzQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.ORCID 0000000281922175
J N UllomQuantum Electromagnetics Division, National Institute of Standards and Technology, Boulder, Colorado 80305, USA.
Yu RalchenkoQuantum Measurement Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.ORCID 0000000300839554

Funding

Intramural NIST DOC 9999-NIST
6 · The paper itself

Abstract

We report on the design, commissioning, and initial measurements of a Transition-Edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ∼30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8000 eV and achieve an energy resolution of 3.7 eV-5.0 eV over this range, a more modest (<2×) improvement over the previous microcalorimeters. Beyond this energy range, NETS can operate with various trade-offs, the most significant of which are reduced efficiency at lower energies and being limited to a subset of the pixels at higher energies. As an initial demonstration of the capabilities of NETS, we measured transitions in He-like and H-like O, Ne, and Ar as well as Ni-like W. We detail the energy calibration and data analysis techniques used to transform detector counts into x-ray spectra, a process that will be the basis for analyzing future data.

Identifiers

PMID31893849
PMCPMC8772522

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.