ArticleACS omega2019
Anthocyanin-Functionalized Contact Lens Sensors for Ocular pH Monitoring.
Article in ACS omega, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 78 citations in OpenAlex.
- Nanomaterial-enabled smart contact lenses: bridging sensing, therapy, and theranostics for next-generation ocular healthcare.Journal of nanobiotechnology · 2026Review
- Recent advances in smart contact lenses.Biosensors & bioelectronics: X · 2026Article
- Anthocyanin (ATH)-incorporating polyvinylpyrrolidone-ethyl cellulose-(2-hydroxypropyl)-β-cyclodextrin (PVP-EC-BCD) nanofiber-based pH sensor for ocular pH detection during accidental chemical spills.Nanoscale advances · 2026Article
- Optical Contact Lenses Biosensors.ACS sensors · 2025Review
- Current advances in multi-strategy collaborative sensitization for self-powered electrochemical biosensors and their applications in disease biomarker detection.Mikrochimica acta · 2025Review
- Antifouling Polymer-Coated Anthocyanin-Loaded Cellulose Nanocrystals Demonstrate Reduced Bacterial Detection Capabilities.Polymers · 2025Article
- Antifouling Coatings Inspired by Biological Templates.Macromolecular rapid communications · 2025Review
- Microfluidic contact lens: fabrication approaches and applications.Microsystems & nanoengineering · 2025Review
- Natural Pigments-Based Two-Component White Light Emitting Systems.Journal of fluorescence · 2025Article
- Tear-Based Ocular Wearable Biosensors for Human Health Monitoring.Biosensors · 2024Review
- Vat photopolymerization printing of functionalized hydrogels on commercial contact lenses.Scientific reports · 2024Article
- Anthocyanin-Loaded Polymers as Promising Nature-Based, Responsive, and Bioactive Materials.Polymers · 2024Review
- Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management.Chemical reviews · 2023Review
- Glasswing-Butterfly-Inspired Multifunctional Scleral Lens and Smartphone Raman Spectrometer for Point-of-Care Tear Biomarker Analysis.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023Article
- Review
- Fluorescence Sensing Technologies for Ophthalmic Diagnosis.ACS sensors · 2022Review
- Lab-on-a-Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics.Advanced materials (Deerfield Beach, Fla.) · 2022Review
- Syntheses of Gold and Silver Nanocomposite Contact Lenses via Chemical Volumetric Modulation of Hydrogels.ACS biomaterials science & engineering · 2022Article
- Wearable Smart Contact Lenses for Continual Glucose Monitoring: A Review.Frontiers in medicine · 2022Review
- Ophthalmic Sensors and Drug Delivery.ACS sensors · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Anthocyanins are bioactive compounds naturally found in a variety of leaves, fruits, and vegetables. Anthocyanin pigments undergo a modification in their chemical structure when exposed to different concentrations of hydrogen ions, and they were extensively studied to be used as active elements in biocompatible pH sensors. The ocular pH is a significant parameter to assess the ocular physiology in cases of postocular surgery, keratoconjunctivitis, and ocular rosacea. Contact lenses have the potential to be used as medical diagnostic devices for in situ continuous monitoring of the ocular physiology. Here, anthocyanin-functionalized contact lenses were developed as wearable sensors to monitor the ocular pH. Anthocyanin pigments were extracted from
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.