Evidence map›Paper›PMID 31890883›Full record

ArticleLaryngoscope investigative otolaryngology2019

Three-dimensional imaging of upper esophageal sphincter resting pressure.

Shun-Ichi Chitose, Yasuro Shin, Kiminori Sato, Sachiyo Hamakawa, Mioko Fukahori, Takeharu Ono, Hirohito Umeno

Open access · goldAbstract read
In one paragraph

Article in Laryngoscope investigative otolaryngology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. [Development of a balloon sensor device for force-electrical coupling measurement of esophagus].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  2. Review
  3. Article
  4. Article
  5. Three-dimensional imaging of upper esophageal sphincter resting pressure.Laryngoscope investigative otolaryngology · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Shun-Ichi ChitoseDepartment of Otolaryngology-Head and Neck Surgery Kurume University School of Medicine Kurume Japan.ORCID https://orcid.org/0000-0002-9307-2331
Yasuro ShinDepartment of Otolaryngology-Head and Neck Surgery Kurume University School of Medicine Kurume Japan.
Kiminori SatoDepartment of Otolaryngology-Head and Neck Surgery Kurume University School of Medicine Kurume Japan.ORCID https://orcid.org/0000-0001-5415-0176
Sachiyo HamakawaDepartment of Otolaryngology-Head and Neck Surgery Kurume University School of Medicine Kurume Japan.
Mioko FukahoriDepartment of Otolaryngology-Head and Neck Surgery Kurume University School of Medicine Kurume Japan.
Takeharu OnoDepartment of Otolaryngology-Head and Neck Surgery Kurume University School of Medicine Kurume Japan.ORCID https://orcid.org/0000-0003-2414-7034
Hirohito UmenoDepartment of Otolaryngology-Head and Neck Surgery Kurume University School of Medicine Kurume Japan.
Kurume University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveHigh-resolution manometry (HRM) is used to analyze upper esophageal sphincter (UES) physiology. Conventional HRM can yield imprecise measurements of UES resting pressure given its unidirectional sensors and averaging of circumferential pressure. In contrast, three-dimensional (3D) measurements can yield precise UES resting pressure data over the entire length of the UES. This study conducted a detailed analysis of UES resting pressure as evaluated by 3D-HRM.

methodsSeventeen young, healthy adult participants (7 females and 10 males) were recruited. The 3D-HRM system used includes a pressure sensor catheter (outer diameter, 4 mm) and eight-channel transducers arranged circumferentially to acquire pressure data at 45° intervals. The catheter was inserted transnasally into the esophagus and automatically retracted at a speed of 1 mm/s. Participants performed the following tasks: maintain resting breathing, perform breath holding, and perform the Valsalva maneuver. Data were obtained and compared per millimeter over the longitudinal UES length.

resultsClear 3D waveforms were identified, with greater mean UES pressures in anterior-posterior directions than in lateral directions (

conclusionsThe normal UES resting pressure was not directionally uniform in the luminal structure. 3D-HRM imaging of UES resting pressure can help deepen our understanding of UES physiology. LEVEL OF EVIDENCE: 4.

Indexed as

high‐resolution manometrypharynxresting pressureswallowing pressureupper esophageal sphincter

Identifiers

PMID31890883
PMCPMC6929582
OpenAlexW2988770653

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.