ArticleRegenerative therapy2019
Effect of mechanical vibration stress in cell culture on human induced pluripotent stem cells.
Article in Regenerative therapy, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 23 citations in OpenAlex.
- Ambient intelligence-based framework for quantitative evaluation of cell culture operations to support standardization and training.Regenerative therapy · 2026Article
- Early and non-destructive prediction of the differentiation efficiency of human induced pluripotent stem cells using imaging and machine learning.Scientific reports · 2025Article
- Diversity of Effects of Mechanical Influences on Living Systems and Aqueous Solutions.International journal of molecular sciences · 2025Review
- Using magnetic resonance relaxometry to evaluate the safety and quality of induced pluripotent stem cell-derived spinal cord progenitor cells.Stem cell research & therapy · 2024Article
- Microgravity triggers ferroptosis and accelerates senescence in the MG-63 cell model of osteoblastic cells.NPJ microgravity · 2023Article
- Characterization of Mechanical and Cellular Effects of Rhythmic Vertical Vibrations on Adherent Cell Cultures.Bioengineering (Basel, Switzerland) · 2023Article
- Simple and efficient differentiation of human iPSCs into contractible skeletal muscles for muscular disease modeling.Scientific reports · 2023Article
- Article
- Approach of resource expenditure estimation toward mechanization in the manufacturing of cell-based products.Regenerative therapy · 2022Article
- Design, Fabrication, Testing and Simulation of a Rotary Double Comb Drives Actuated Microgripper.Micromachines · 2021Article
- A Variable Scheduling Maintenance Culture Platform for Mammalian Cells.SLAS technology · 2021Article
- An Automated Organoid Platform with Inter-organoid Homogeneity and Inter-patient Heterogeneity.Cell reports. Medicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The development of induced pluripotent stem cell (iPSC) techniques has solved various limitations in cell culture including cellular proliferation and potency. Hence, the expectations on wider applications and the quality of manufactured iPSCs are rapidly increasing. To answer such growing expectations, enhancement of technologies to improve cell-manufacturing efficiency is now a challenge for the bioengineering field. Mechanization of conventional manual operations, aimed at automation of cell manufacturing, is quickly advancing. However, as more processes are being automated in cell manufacturing, it is need to be more critical about influential parameters that may not be as important in manual operations. As a model of such parameters, we focused on the effect of mechanical vibration, which transmits through the vessel to the cultured iPSCs. We designed 7 types of vertical vibration conditions in cell culture vessels using a vibration calibrator. These conditions cover a wide range of potential situations in cell culture, such as tapping or closing an incubator door, and examined their effects by continuous passaging (P3 to P5). Detailed evaluation of cells by time-course image analysis revealed that vibrations can enhance cell growth as an early effect but can negatively affect cell adhesion and growth profile after several passages as a delayed effect. Such unexpected reductions in cell quality are potentially critical issues in maintaining consistency in cell manufacturing. Therefore, this work reveals the importance of continuous examination across several passages with detailed, temporal, quantitative measurements obtained by non-invasive image analysis to examine when and how the unknown parameters will affect the cell culture processes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.