Evidence map›Paper›PMID 31888535›Full record

ArticleBMC medical imaging2019

Automated classification of dense calcium tissues in gray-scale intravascular ultrasound images using a deep belief network.

Juhwan Lee, Yoo Na Hwang, Ga Young Kim, Ji Yean Kwon, Sung Min Kim

Abstract read
In one paragraph

Article in BMC medical imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Recent Trends in Artificial Intelligence-Assisted Coronary Atherosclerotic Plaque Characterization.International journal of environmental research and public health · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Juhwan LeeDepartment of Biomedical Engineering, Case Western Reserve University, 10900, Euclid Avenue, Cleveland, OH, 44106, USA.
Yoo Na HwangDepartment of Medical Biotechnology, Dongguk University-Bio Medi Campus, (10326) 32, Dongguk-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, Republic of Korea.
Ga Young KimDepartment of Medical Biotechnology, Dongguk University-Bio Medi Campus, (10326) 32, Dongguk-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, Republic of Korea.
Ji Yean KwonDepartment of Medical Devices Industry, Dongguk University-Seoul, (04620) 30, Pildong-ro 1-gil, Jung-gu, Seoul, Republic of Korea.
Sung Min KimDepartment of Medical Biotechnology, Dongguk University-Bio Medi Campus, (10326) 32, Dongguk-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, Republic of Korea. smkim@dongguk.edu.ORCID 0000-0001-6457-989X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIVUS is widely used to quantitatively assess coronary artery disease. The purpose of this study was to automatically characterize dense calcium (DC) tissue in the gray scale intravascular ultrasound (IVUS) images using the image textural features.

methodsA total of 316 Gy-scale IVUS and corresponding virtual histology images from 26 patients with acute coronary syndrome who underwent IVUS along with X-ray angiography between October 2009 to September 2014 were retrospectively acquired and analyzed. One expert performed all procedures and assessed their IVUS scans. After image acquisition, the DC candidate and corresponding acoustic shadow regions were automatically determined. Then, nine image-base feature groups were extracted from the DC candidates. In order to reduce the dimensionalities, principal component analysis (PCA) was performed, and selected feature sets were utilized as an input for a deep belief network. Classification results were validated using 10-fold cross validation.

resultsThe dimensionality of the feature map was efficiently reduced by 50% (from 66 to 33) without any performance decrease using PCA method. Sensitivity, specificity, and accuracy of the proposed method were 92.8 ± 0.1%, 85.1 ± 0.1%, and 88.4 ± 0.1%, respectively (p < 0.05). We found that the window size could largely influence the characterization results, and selected the 5 × 5 size as the best condition. We also validated the performance superiority of the proposed method with traditional classification methods.

conclusionsThese experimental results suggest that the proposed method has significant clinical applicability for IVUS-based cardiovascular diagnosis.

Indexed as

Acute Coronary SyndromeAlgorithmsAngiographyCoronary VesselsHumansPrincipal Component AnalysisRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsRetrospective StudiesSensitivity and SpecificityUltrasonography, InterventionalDeep belief networkDense calciumIntravascular ultrasoundTextural feature

Identifiers

PMID31888535
PMCPMC6937730

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.