Evidence map›Paper›PMID 31888176›Full record

ArticleSensors (Basel, Switzerland)2019

A Pilot Study on Falling-Risk Detection Method Based on Postural Perturbation Evoked Potential Features.

Shenglong Jiang, Hongzhi Qi, Jie Zhang, Shufeng Zhang, Rui Xu, Yuan Liu, Lin Meng, Dong Ming

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shenglong JiangSchool of Precision Instrument & Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Hongzhi QiSchool of Precision Instrument & Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Jie ZhangSchool of Precision Instrument & Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Shufeng ZhangSchool of Precision Instrument & Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Rui XuSchool of Precision Instrument & Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Yuan LiuAcademy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China.
Lin MengAcademy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China.ORCID 0000-0001-9787-9936
Dong MingSchool of Precision Instrument & Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.

Funding

National Key Research and Development Program of China 2017YFB1300302National Natural Science Foundation of China 81601565National Natural Science Foundation of China 81630051National Natural Science Foundation of China 91648122Tianjin Key Technology R&D Program 16ZXHLSY00270Tianjin Key Technology R&D Program 17ZXRGGX00020
6 · The paper itself

Abstract

In the human-robot hybrid system, due to the error recognition of the pattern recognition system, the robot may perform erroneous motor execution, which may lead to falling-risk. While, the human can clearly detect the existence of errors, which is manifested in the central nervous activity characteristics. To date, the majority of studies on falling-risk detection have focused primarily on computer vision and physical signals. There are no reports of falling-risk detection methods based on neural activity. In this study, we propose a novel method to monitor multi erroneous motion events using electroencephalogram (EEG) features. There were 15 subjects who participated in this study, who kept standing with an upper limb supported posture and received an unpredictable postural perturbation. EEG signal analysis revealed a high negative peak with a maximum averaged amplitude of -14.75 ± 5.99 μV, occurring at 62 ms after postural perturbation. The xDAWN algorithm was used to reduce the high-dimension of EEG signal features. And, Bayesian linear discriminant analysis (BLDA) was used to train a classifier. The detection rate of the falling-risk onset is 98.67%. And the detection latency is 334ms, when we set detection rate beyond 90% as the standard of dangerous event onset. Further analysis showed that the falling-risk detection method based on postural perturbation evoked potential features has a good generalization ability. The model based on typical event data achieved 94.2% detection rate for unlearned atypical perturbation events. This study demonstrated the feasibility of using neural response to detect dangerous fall events.

Indexed as

brain–computer interface (BCI)cross-task recognitionelectroencephalogram (EEG)falling-risk detectionmachine learningpostural perturbation

Identifiers

PMID31888176
PMCPMC6960671

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390