Evidence map›Paper›PMID 31882678›Full record

ArticleScientific reports2019

Generating Bessel beams with broad depth-of-field by using phase-only acoustic holograms.

Sergio Jiménez-Gambín, Noé Jiménez, José M Benlloch, Francisco Camarena

Abstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Review
  3. Feasibility of Hologram-Assisted Bilateral Blood-Brain Barrier Opening in Non-Human Primates.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Article
  4. Article
  5. Article
  6. Underwater acoustic metamaterials.National science review · 2023
    Review
  7. Article
  8. Article
  9. Acoustic Holograms for Bilateral Blood-Brain Barrier Opening in a Mouse Model.IEEE transactions on bio-medical engineering · 2022
    Article
  10. Review
  11. Review
  12. Ring-Focusing Fresnel Acoustic Lens for Long Depth-of-Focus Focused Ultrasound with Multiple Trapping Zones.Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sergio Jiménez-GambínInstituto de Instrumentación para Imagen Molecular, Consejo Superior de Investigaciones Científicas, Universitat Politècnica de València, Camino de Vera S/N, 446022, València, Spain.
Noé JiménezInstituto de Instrumentación para Imagen Molecular, Consejo Superior de Investigaciones Científicas, Universitat Politècnica de València, Camino de Vera S/N, 446022, València, Spain. nojigon@upv.es.ORCID http://orcid.org/0000-0002-6539-670X
José M BenllochInstituto de Instrumentación para Imagen Molecular, Consejo Superior de Investigaciones Científicas, Universitat Politècnica de València, Camino de Vera S/N, 446022, València, Spain.
Francisco CamarenaInstituto de Instrumentación para Imagen Molecular, Consejo Superior de Investigaciones Científicas, Universitat Politècnica de València, Camino de Vera S/N, 446022, València, Spain.

Funding

EC | European Regional Development Fund (Europski Fond za Regionalni Razvoj) IDIFEDER/2018/022Generalitat Valenciana (Regional Government of Valencia) ACIF/2017/045
6 · The paper itself

Abstract

We report zero-th and high-order acoustic Bessel beams with broad depth-of-field generated using acoustic holograms. While the transverse field distribution of Bessel beams generated using traditional passive methods is correctly described by a Bessel function, these methods present a common drawback: the axial distribution of the field is not constant, as required for ideal Bessel beams. In this work, we experimentally, numerically and theoretically report acoustic truncated Bessel beams of flat-intensity along their axis in the ultrasound regime using phase-only holograms. In particular, the beams present a uniform field distribution showing an elongated focal length of about 40 wavelengths, while the transverse width of the beam remains smaller than 0.7 wavelengths. The proposed acoustic holograms were compared with 3D-printed fraxicons, a blazed version of axicons. The performance of both phase-only holograms and fraxicons is studied and we found that both lenses produce Bessel beams in a wide range of frequencies. In addition, high-order Bessel beam were generated. We report first order Bessel beams that show a clear phase dislocation along their axis and a vortex with single topological charge. The proposed method may have potential applications in ultrasonic imaging, biomedical ultrasound and particle manipulation applications using passive lenses.

Identifiers

PMID31882678
PMCPMC6934506

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.