Evidence map›Paper›PMID 31882622›Full record

ArticleScientific reports2019

Electrokinetic Mixing for Improving the Kinetics of an HbA1c Immunoassay.

Emir Yasun, Travis Trusty, Rania W Abolhosn, Nigel J Clarke, Igor Mezić

Abstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Emir YasunDepartment of Mechanical Engineering and Biological Nanostructures Laboratory, California NanoSystems Institute (CNSI), University of California, Santa Barbara, Santa Barbara, CA, 93106, USA.ORCID http://orcid.org/0000-0002-3930-0049
Travis TrustyDepartment of Mechanical Engineering and Biological Nanostructures Laboratory, California NanoSystems Institute (CNSI), University of California, Santa Barbara, Santa Barbara, CA, 93106, USA.
Rania W AbolhosnQuest Diagnostics Nichols Institute, Advanced Technology R&D, 33608 Ortega Hwy, San Juan Capistrano, CA, 92675, USA.
Nigel J ClarkeQuest Diagnostics Nichols Institute, Advanced Technology R&D, 33608 Ortega Hwy, San Juan Capistrano, CA, 92675, USA.
Igor MezićDepartment of Mechanical Engineering and Biological Nanostructures Laboratory, California NanoSystems Institute (CNSI), University of California, Santa Barbara, Santa Barbara, CA, 93106, USA. mezic@ucsb.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The efficiency of the diagnostic platforms utilizing ELISA technique or immunoassays depends highly on incubation times of the recognition elements or signaling molecules and volume of the patient samples. In conventional immunoassays, long incubation times and excess amounts of the recognition and signaling molecules are used. The technology proposed here uses electrokinetic mixing of the reagents involved in a sandwich immunoassay based diagnostic assay in electrode-enabled microwell plates in such a way that the incubation times and volumes can be reduced substantially. The integration of the electrodes at the bottom of the conventional microwell plates ensures that the motions of the liquid flows in the wells can be controlled through the application of high frequency AC current along these electrodes. The strategy to generate chaotic mixing by modification of standard multiwell plates, enables its use in high throughput screening, in contrast to microfluidic channel-based technologies that are difficult to incorporate into conventional plates. An immunoassay for detection of glycated hemoglobin (HbA1c) that can reveal a patient's average level of blood sugar from the past 2-3 months instead of just measuring the current levels and thereby constitutes a reliable diabetes monitoring platform was chosen as a pilot assay for technology demonstration. The overall incubation time for the assay was reduced by approximately a factor of five when electrokinetic mixing was employed. Furthermore, when the quantity of the reagents was reduced by half, almost no distinguishable signals could be obtained with conventional immunoassay, while electrokinetic mixing still facilitated acquisition of signals while varying concentration of the glycated hemoglobin. There was also a substantial difference in the signal intensities especially for the low concentrations of the HbA1c obtained from electrokinetic mixing assisted and conventional immunoassay when the quantity of the reagents and incubation times were kept constant, which is also an indication of the increase in bioassay efficiency. The electrokinetic mixing technique has the potential to improve the efficiency of immunoassay based diagnostic platforms with reduced assay time and reagent amounts, leading to higher throughput analysis of clinical samples. It may also open new avenues in point of care diagnostic devices, where kinetics and sampling size/volume play a critical role.

Indexed as

Electrochemical TechniquesGlycated HemoglobinHumansImmunoassayKineticsGlycated Hemoglobinhemoglobin A1c protein, human

Identifiers

PMID31882622
PMCPMC6934526

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.