Evidence map›Paper›PMID 31881029›Full record

ArticlePloS one2019

Improving accuracy for finite element modeling of endovascular coiling of intracranial aneurysm.

Robert J Damiano, Vincent M Tutino, Saeb R Lamooki, Nikhil Paliwal, Gary F Dargush, Jason M Davies, Adnan H Siddiqui, Hui Meng

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Robert J DamianoDepartment of Mechanical and Aerospace Engineering, University at Buffalo, State University of New York, Buffalo, New York, United States of America.ORCID 0000-0003-2256-2154
Vincent M TutinoCanon Stroke & Vascular Research Center, University at Buffalo, State University of New York, Buffalo, New York, United States of America.
Saeb R LamookiDepartment of Mechanical and Aerospace Engineering, University at Buffalo, State University of New York, Buffalo, New York, United States of America.
Nikhil PaliwalDepartment of Mechanical and Aerospace Engineering, University at Buffalo, State University of New York, Buffalo, New York, United States of America.
Gary F DargushDepartment of Mechanical and Aerospace Engineering, University at Buffalo, State University of New York, Buffalo, New York, United States of America.
Jason M DaviesDepartment of Neurosurgery, University at Buffalo, State University of New York, Buffalo, New York, United States of America.
Adnan H SiddiquiCanon Stroke & Vascular Research Center, University at Buffalo, State University of New York, Buffalo, New York, United States of America.
Hui MengDepartment of Mechanical and Aerospace Engineering, University at Buffalo, State University of New York, Buffalo, New York, United States of America.
University at Buffalo, State University of New York · US

Funding

Institutional Career DevelopmentKL2TR001413 · NCATS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI DUBOCOVICH, MARGARITA L · 2015 to 2024
$4.2M
Virtual Intervention of Intracranial AneurysmsR01NS091075 · NINDS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI MENG, HUI · 2015 to 2019
$1.7M
NCATS NIH HHS KL2 TR001413NINDS NIH HHS R01 NS091075
6 · The paper itself

Abstract

backgroundComputer modeling of endovascular coiling intervention for intracranial aneurysm could enable a priori patient-specific treatment evaluation. To that end, we previously developed a finite element method (FEM) coiling technique, which incorporated simplified assumptions. To improve accuracy in capturing real-life coiling, we aimed to enhance the modeling strategies and experimentally test whether improvements lead to more accurate coiling simulations.

methodsWe previously modeled coils using a pre-shape based on mathematical curves and mechanical properties based on those of platinum wires. In the improved version, to better represent the physical properties of coils, we model coil pre-shapes based on how they are manufactured, and their mechanical properties based on their spring-like geometric structures. To enhance the deployment mechanics, we include coil advancement to the aneurysm in FEM simulations. To test if these new strategies produce more accurate coil deployments, we fabricated silicone phantoms of 2 patient-specific aneurysms in duplicate, deployed coils in each, and quantified coil distributions from intra-aneurysmal cross-sections using coil density (CD) and lacunarity (L). These deployments were simulated 9 times each using the original and improved techniques, and CD and L were calculated for cross-sections matching those in the experiments. To compare the 2 simulation techniques, Euclidean distances (dMin, dMax, and dAvg) between experimental and simulation points in standardized CD-L space were evaluated. Univariate tests were performed to determine if these distances were significantly different between the 2 simulations.

resultsCoil deployments using the improved technique agreed better with experiments than the original technique. All dMin, dMax, and dAvg values were smaller for the improved technique, and the average values across all simulations for the improved technique were significantly smaller than those from the original technique (dMin: p = 0.014, dMax: p = 0.013, dAvg: p = 0.045).

conclusionIncorporating coil-specific physical properties and mechanics improves accuracy of FEM simulations of endovascular intracranial aneurysm coiling.

Indexed as

Blood Vessel ProsthesisEndovascular ProceduresFinite Element AnalysisHumansIntracranial AneurysmModels, Biological

Identifiers

PMID31881029
PMCPMC6934293
OpenAlexW2998097154

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.