[Timing calibration comparison research of integrated TOF-PET/MR].

Tianyi Zeng, Hui Yang, Tuoyu Cao, Lingzhi Hu, Xu Chu, Xinyu Lu, Qun Chen

Abstract read
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tianyi ZengShanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, P.R.China;University of Chinese Academy of Sciences, Beijing 100049, P.R.China.
Hui YangShanghai United Imaging Healthcare Co., Ltd., Shanghai 201807, P.R.China.
Tuoyu CaoShanghai United Imaging Healthcare Co., Ltd., Shanghai 201807, P.R.China.
Lingzhi HuShanghai United Imaging Healthcare Co., Ltd., Shanghai 201807, P.R.China.
Xu ChuShanghai United Imaging Healthcare Co., Ltd., Shanghai 201807, P.R.China.
Xinyu LuShanghai United Imaging Healthcare Co., Ltd., Shanghai 201807, P.R.China.
Qun ChenShanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, P.R.China;Shanghai United Imaging Healthcare Co., Ltd., Shanghai 201807, P.R.China.qun.chen@sari.ac.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Integrated TOF-PET/MR is a multimodal imaging system which can acquire high-quality magnetic resonance (MR) and positron emission tomography (PET) images at the same time, and it has time of flight (TOF) function. The TOF-PET system usually features better image quality compared to traditional PET because it is capable of localizing the lesion on the line of response where annihilation takes place. TOF technology measures the time difference between the detectors on which the two 180-degrees-seperated photons generated from positron annihilation are received. Since every individual crystal might be prone to its timing bias, timing calibration is needed for a TOF-PET system to work properly. Three approaches of timing calibration are introduced in this article. The first one named as fan-beam method is an iterative method that measures the bias of the Gaussian distribution of timing offset created from a fan-beam area constructed using geometric techniques. The second one is to find solutions of the overdetermination equations set using L1 norm minimization and is called L1-norm method. The last one called L2-norm method is to build histogram of the TOF and find the peak, and uses L2 norm minimization to get the result. This article focuses on the comparison of the amount of the data and the calculation time needed by each of the three methods. To avoid location error of the cylinder radioactive source during data collection, we developed a location calibration algorithm which could calculate accurate position of the source and reduce image artifacts. The experiment results indicate that the three approaches introduced in this article could enhance the qualities of PET images and standardized uptake values of cancer regions, so the timing calibration of integrated TOF-PET/MR system was realized. The fan-beam method has the best image quality, especially in small lesions. In integrated TOF-PET/MR timing calibration, we recommend using fan-beam method.

Indexed as

Magnetic Resonance ImagingPositron-Emission TomographyAlgorithmsCalibrationImage Processing, Computer-AssistedMagnetic Resonance SpectroscopyMultimodal Imagingfan-beamintegrated TOF-PET/MRnorm minimizationtiming calibration

Identifiers

PMID31875375
PMCPMC9935176

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.