ArticleMedical physics2020
Is high sensitivity always desirable for a grating-based differential phase contrast imaging system?
Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeIn grating-based x-ray differential phase contrast (DPC) imaging, the measured signal amplitude of the phase shift induced by an image object is proportional to the so-called system sensitivity. Therefore, to achieve a better signal-to-noise (SNR) for improved imaging performance, it is generally believed that one should increase the system sensitivity by reducing the period of the analyzer grating or increasing the distance between the phase grating and analyzer grating. The purpose of this work is to theoretically and experimentally demonstrate that there is an optimal system sensitivity to attain the highest SNR for a given task provided that the standard phase-stepping acquisition and phase retrieval methods are used. When system sensitivity goes beyond this optimal value, SNR decreases and the imaging performance deteriorates.
methodsDue to the fundamental fact that the measured phase signal is a cyclic variable, the phase wrapping effect is inevitable in DPC imaging when the system sensitivity increases. The phase wrapping effect appears in both signal and noise measurements. The effect in the signal measurement is manifested in the so-called signal statistical bias and such effect often impacts the accuracy of the measurement. The phase wrapping effect also appears in the noise variance measurement and impacts the precision of the measurement. A thorough theoretical analysis was performed in this work to demonstrate the quantitative impacts of phase wrapping on both signal bias and noise variance and thus on the actual system SNR. The joint effect of phase wrapping in both the signal bias and noise variance yields an optimal system sensitivity to achieve the highest SNR. Both extensive numerical simulation studies and experimental studies were performed to validate the theoretical analysis.
resultsBoth theoretical analysis and experimental studies show that the SNR of the DPC signal is not always proportional to the sensitivity due to the cyclic nature of the signal and the phase wrapping effect. For a given refraction angle and exposure level, there exists an optimal sensitivity factor that maximizes the SNR, beyond which, increasing the sensitivity will decrease the SNR.
conclusionsIncrease of system sensitivity does not always improve x-ray DPC imaging performance provided that the standard phase-stepping acquisition and phase retrieval methods are used.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.