Evidence map›Paper›PMID 31872019›Full record

ArticleTrauma case reports2019

Augmentation of simultaneous acetabular and femoral neck fracture in osteogenesis imperfecta using photodynamic bone stabilization - A case report.

Sebastian Pesch, Alexander Gromer, Marc Beirer, Stefan Huber-Wagner, Peter Biberthaler, Chlodwig M Kirchhoff

Open access · goldAbstract readCase Reports
In one paragraph

Article in Trauma case reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Sebastian PeschDepartment of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Alexander GromerDepartment of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Marc BeirerDepartment of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Stefan Huber-WagnerDepartment of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Peter BiberthalerDepartment of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Chlodwig M KirchhoffDepartment of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
Technical University of Munich · DEKlinikum rechts der Isar · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSurgical fracture treatment in patients suffering from "osteogenesis imperfecta" (OI) is challenging and often results in unsatisfactory fixation of implants due to altered bone quality. Even the use of locking plates bears a residual risk to develop a loss of reduction leading to secondary fracture dislocation. However, the augmentation with an intramedullary photodynamic bone stabilization system (PBS) (e.g. Illuminoss®) may increase bone stability and allow for a sufficient anchorage of established implants even in OI patients. CASE PRESENTATION: We report the case of a 41-year-old male patient with the diagnosis of OI. He sustained a medial femoral neck fracture (Garden type IV, Pauwels type III) and a fracture of the acetabulum (AO-Type 62-B.3) - both right-sided - after a blunt trauma during a bicycle accident. The medial femoral neck fracture was subsequently surgically treated to preserve the femoral head. After augmentation of the proximal femur with the PBS, a Dynamic Hip Screw (DHS) was implanted. After a short recovery, the acetabular fracture was surgically treated by intramedullary augmentation and locking plate fixation.The patient was discharged seven days after the surgical intervention of the acetabular fracture. Partial weight-bearing activities of the right lower extremity were performed on crutches for 6 weeks. The patient was able to do his outpatient rehabilitation program without any complications. He returned to work eight weeks after surgery. After a follow-up of four months, the patient presented full weight-bearing without assistance. No physical complaints were reported 14 months after surgery (Harris Hip Score 90).

conclusionTo the best of our knowledge, we report the augmentation with a photodynamic bone stabilization system of internal fixation techniques in an OI patient with fractures of the femoral neck and the acetabulum for the first time. This advanced surgical procedure shows the high potential of intramedullary photodynamic bone stabilization in patients with minor bone quality.

Indexed as

Bone augmentationFracture treatmentIlluminoss®Osteogenesis imperfectaPhotodynamic bone stabilization system

Identifiers

PMID31872019
PMCPMC6911912
OpenAlexW2945550111

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.