In one paragraph

Article in The British journal of ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 22 citations in OpenAlex.

  1. Validation of a New Handheld Automated Fixed-Force Applanation Tonometer.Translational vision science & technology · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Artificial intelligence in the anterior segment of eye diseases.International journal of ophthalmology · 2024
    Review
  7. Article
  8. Chronic Kidney Disease as a Cardiovascular Disorder-Tonometry Data Analyses.International journal of environmental research and public health · 2022
    Observational
  9. [Is home perimetry possible?]Archivos de la Sociedad Espanola de Oftalmologia · 2021
    Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Yue WuOphthalmology, University of Washington, Seattle, Washington, USA.
Ian LuttrellOphthalmology, University of Washington, Seattle, Washington, USA.
Shu FengUniversity of Washington, Seattle, Washington, USA.
Philip P ChenUniversity of Washington, Seattle, Washington, USA.
Ted SpaideUniversity of Washington, Seattle, Washington, USA.
Aaron Y Lee *University of Washington, Seattle, Washington, USA.
Joanne C Wen *Ophthalmology, Duke University, Durham, North Carolina, USA joanne.wen@duke.edu.ORCID 0000-0002-8407-7819
University of Washington · USDuke University · US

Funding

Epidemiology and clinical outcomes of diabetic macular edemaK23EY029246 · NEI · UNIVERSITY OF WASHINGTON · PI LEE, AARON · 2018 to 2022
$1.1M
NEI NIH HHS K23 EY029246
6 · The paper itself

Abstract

BACKGROUND/

aimsTo compare intraocular pressure (IOP) measurements using a prototype smartphone tonometer with other tonometers used in clinical practice.

methodsPatients from an academic glaucoma practice were recruited. The smartphone tonometer uses fixed force applanation and in conjunction with a machine-learning computer algorithm is able to calculate the IOP. IOP was also measured using Goldmann applanation tonometry (GAT) in all subjects. A subset of patients were also measured using ICare, pneumotonometry (upright and supine positions) and Tono-Pen (upright and supine positions) and the results were compared.

results92 eyes of 81 subjects were successfully measured. The mean difference (in mm Hg) for IOP measurements of the smartphone tonometer versus other devices was +0.24 mm Hg for GAT, -1.39 mm Hg for ICare, -3.71 mm Hg for pneumotonometry and -1.30 mm Hg for Tono-Pen. The 95% limits of agreement for the smartphone tonometer versus other devices was -4.35 to 4.83 mm Hg for GAT, -6.48 to 3.70 mm Hg for ICare, -7.66 to -0.15 mm Hg for pneumotonometry and -5.72 to 3.12 mm Hg for Tono-Pen. Overall, the smartphone tonometer results correlated best with GAT (R

conclusionsPreliminary IOP measurements using a prototype smartphone-based tonometer was grossly equivalent to the reference standard.

Indexed as

Machine LearningAdultAgedFemaleGlaucoma, Angle-ClosureGlaucoma, Open-AngleHumansIntraocular PressureLow Tension GlaucomaMaleMiddle AgedOcular HypertensionPilot ProjectsReproducibility of ResultsSmartphoneTonometry, Ocularintraocular pressure

Identifiers

PMID31871048
PMCPMC7397723
OpenAlexW2995331514

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked