Evidence map›Paper›PMID 31868744›Full record

ArticleJournal of synchrotron radiation2020

Translative lens-based full-field coherent X-ray imaging.

Carsten Detlefs, Mario Alejandro Beltran, Jean Pierre Guigay, Hugh Simons

Open access · hybridAbstract read
In one paragraph

Article in Journal of synchrotron radiation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Carsten DetlefsEuropean Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex, France.
Mario Alejandro BeltranDepartment of Physics, Technical University of Denmark, 2800 Kgs Lyngby, Denmark.
Jean Pierre GuigayEuropean Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex, France.
Hugh SimonsDepartment of Physics, Technical University of Denmark, 2800 Kgs Lyngby, Denmark.ORCID 0000-0002-3093-9241
European Synchrotron Radiation Facility · FRTechnical University of Denmark · DK

Funding

Villum Fonden 17616
6 · The paper itself

Abstract

A full-field coherent imaging approach suitable for hard X-rays based on a classical (i.e. Galilean) X-ray microscope is described. The method combines a series of low-resolution images acquired at different transverse lens positions into a single high-resolution image, overcoming the spatial resolution limit set by the numerical aperture of the objective lens. The optical principles of the approach are described, the successful reconstruction of simulated phantom data is demonstrated, and aspects of the reconstruction are discussed. The authors believe that this approach offers some potential benefits over conventional scanning X-ray ptychography in terms of spatial bandwidth and radiation dose rate.

Indexed as

coherenceimagingmicroscopy

Identifiers

PMID31868744
PMCPMC7842204
OpenAlexW2943547306

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.