ArticleACS omega2019
High-Resolution Rapid Prototyping of Liquid Metal Electronics by Direct Writing on Highly Prestretched Substrates.
Article in ACS omega, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Liquid Metal Patterning and Unique Properties for Next-Generation Soft Electronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023Review
- Advances in Liquid Metal-Enabled Flexible and Wearable Sensors.Micromachines · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A rapid and inexpensive method to produce high-resolution liquid metal patterns and electronics on stretchable substrates was introduced. Two liquid-phase gallium-indium (GaIn) alloy patterns, conductive lines, and interdigitated electrodes, were directly written or shadow mask-printed on a prestretched elastomeric substrate surface. Then, the prestretched substrate was released to recover its original length, and thus, electronic patterns simultaneously shrank on it. After these patterns were transferred to another prestretched substrate by the stamp printing method, the patterning resolution was demonstrated to increase by totally 50 times for the two successive stretch-release-shrink operations. Additionally, the resistance of the handwritten liquid metal conductive line traces remained nearly unchanged during the stretching process, which is believed to be feasible for electrical connections in stretchable electronics. The rapid prototyping of a serpentine strain sensor was successfully demonstrated to be highly sensitive and repeatable with a stretching ratio ranging from 0 to 200%. The proposed method paves a new way to fabricate stretchable electronic devices with high patterning resolution.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.