Evidence map›Paper›PMID 31863910›Full record

ArticleActa biomaterialia2020

Evaluation of a conducting elastomeric composite material for intramuscular electrode application.

X Sally Zheng, Azante Y Griffith, Emily Chang, Michael J Looker, Lee E Fisher, Brady Clapsaddle, X Tracy Cui

Open access · greenAbstract read
In one paragraph

Article in Acta biomaterialia, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Stretchable, Fully Polymeric Electrode Arrays for Peripheral Nerve Stimulation.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

X Sally ZhengDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States.
Azante Y GriffithDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States.
Emily ChangTDA Research Inc., Wheat Ridge, CO 80033, United States.
Michael J LookerTDA Research Inc., Wheat Ridge, CO 80033, United States.
Lee E FisherDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States; Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, United States; Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States.
Brady ClapsaddleTDA Research Inc., Wheat Ridge, CO 80033, United States.
X Tracy CuiDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States; Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States. Electronic address: xic11@pitt.edu.
University of Pittsburgh · USTDA Research (United States) · US

Funding

Improving chronic neural recording performance through biomaterial strategiesR01NS062019 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CUI, XINYAN TRACY · 2008 to 2018
$4.4M
Efficiency and Safety of Microstimulation Via Different Electrode MaterialsR01NS110564 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CUI, XINYAN TRACY · 2019 to 2024
$3.1M
Inhibition of Neural Electrode-mediated Inflammation and Neuronal Cell DeathR01NS089688 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CUI, XINYAN TRACY · 2015 to 2019
$3.1M
Ultra sensitive and flexible MEAs for chronic dopamine detection at both tonic and phasic levelsR21DA049592 · NIDA · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CUI, XINYAN TRACY · 2019 to 2020
$428k
NIDA NIH HHS R21 DA049592NINDS NIH HHS R01 NS062019NINDS NIH HHS R01 NS089688NINDS NIH HHS R01 NS110564
6 · The paper itself

Abstract

Electrical stimulation of the muscle has been proven efficacious in preventing atrophy and/or reanimating paralyzed muscles. Intramuscular electrodes made from metals have significantly higher Young's Moduli than the muscle tissues, which has the potential to cause chronic inflammation and decrease device performance. Here, we present an intramuscular electrode made from an elastomeric conducting polymer composite consisting of PEDOT-PEG copolymer, silicone and carbon nanotubes (CNT) with fluorosilicone insulation. The electrode wire has a Young's modulus of 804 (±99) kPa, which better mimics the muscle tissue modulus than conventional stainless steel (SS) electrodes. Additionally, the non-metallic composition enables metal-artifact free CT and MR imaging. These soft wire (SW) electrodes present comparable electrical impedance to SS electrodes of similar geometric surface area, activate muscle at a lower threshold, and maintain stable electrical properties in vivo up to 4 weeks. Histologically, the SW electrodes elicited significantly less fibrotic encapsulation and less IBA-1 positive macrophage accumulation than the SS electrodes at one and three months. Further phenotyping the macrophages with the iNOS (pro-inflammatory) and ARG-1 (pro-healing) markers revealed significantly less presence of pro-inflammatory macrophage around SW implants at one month. By three months, there was a significant increase in pro-healing macrophages (ARG-1) around the SW implants but not around the SS implants. Furthermore, a larger number of AchR clusters closer to SW implants were found at both time points compared to SS implants. These results suggest that a softer implant encourages a more intimate and healthier electrode-tissue interface. STATEMENT OF SIGNIFICANCE: Intramuscular electrodes made from metals have significantly higher Young's Moduli than the muscle tissues, which has the potential to cause chronic inflammation and decrease device performance. Here, we present an intramuscular electrode made from an elastomeric conducting polymer composite consisting of PEDOT-PEG copolymer, silicone and carbon nanotubes with fluorosilicone insulation. This elastomeric composite results in an electrode wire with a Young's modulus mimicking that of the muscle tissue, which elicits significantly less foreign body response compared to stainless steel wires. The lack of metal in this composite also enables metal-artifact free MRI and CT imaging.

Indexed as

Electrodes, ImplantedAnimalsBiocompatible MaterialsElastomersElectrochemistryMagnetic Resonance ImagingMaleMusclesRats, Sprague-DawleyReceptors, CholinergicX-Ray MicrotomographyBiocompatible Materialselastomeric polymerElastomersReceptors, CholinergicConducting polymerForeign body responseIntramuscular electrodes

Identifiers

PMID31863910
PMCPMC7996067
OpenAlexW2995797975

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.