ArticleMedical physics2020
A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.
Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 34 citations in OpenAlex.
- Feasibility and Safety of CIOS Spin for One-Stop Pulmonary Nodule Localization and Resection.Interdisciplinary cardiovascular and thoracic surgery · 2026Article
- Accuracy and reproducibility of a single-pose image-to-robot registration method for mobile C-arm cone beam CT guided histotripsy.Journal of applied clinical medical physics · 2025Article
- Determinants of radiation exposure during mobile cone-beam CT-guided robotic-assisted bronchoscopy.Respirology (Carlton, Vic.) · 2024Article
- Fully automatic online geometric calibration for non-circular cone-beam CT orbits using fiducials with unknown placement.Medical physics · 2024Article
- Article
- Cone-beam CT in lung biopsy: a clinical practice review on lessons learned and future perspectives.Annals of translational medicine · 2023Review
- Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept.Physics in medicine and biology · 2023Article
- Cone-beam CT sampling incompleteness: analytical and empirical studies of emerging systems and source-detector orbits.Journal of medical imaging (Bellingham, Wash.) · 2023Article
- A C-arm photon counting CT prototype with volumetric coverage using multi-sweep step-and-shoot acquisitions.Physics in medicine and biology · 2022Article
- First clinical experience with a novel, mobile cone-beam CT system for treatment quality assurance in brachytherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2022Article
- QAMaster: A new software framework for phantom-based computed tomography quality assurance.Journal of applied clinical medical physics · 2022Article
- Technical evaluation of the cone-beam computed tomography imaging performance of a novel, mobile, gantry-based X-ray system for brachytherapy.Journal of applied clinical medical physics · 2022Article
- Single-step localization and excision of small pulmonary nodules using a mobile 3D C-arm.Interactive cardiovascular and thoracic surgery · 2021Article
- Article
- Development of a fluoroscopically guided robotic assistant for instrument placement in pelvic trauma surgery.Journal of medical imaging (Bellingham, Wash.) · 2021Article
- Article
- C-arm orbits for metal artifact avoidance (MAA) in cone-beam CT.Physics in medicine and biology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
purposeTo characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D imaging protocols for pertinent imaging tasks.
methodsThe C-arm features a 30 × 30 cm
resultsGeometric calibration showed a high degree of reproducibility despite ~19 mm gantry flex over a nominal semicircular orbit. The dose for a CBCT scan varied from ~0.8-4.7 mGy for head protocols to ~6-38 mGy for body protocols. The MTF was consistent with sub-mm spatial resolution, with f
conclusionThe studies provided objective assessment of the dose and 3D imaging performance of a new C-arm, offering an important basis for clinical deployment and a benchmark for quality assurance. Modifications to standard 3D imaging protocols were identified that may improve performance or reduce radiation dose for pertinent imaging tasks.