Proposal of hemodynamically improved design of an axial flow blood pump for LVAD.

Vikas Kannojiya, Arup Kumar Das, Prasanta Kumar Das

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Vikas KannojiyaMechanical and Industrial Engineering Department, IIT Roorkee, Roorkee, Uttarakhand, 247667, India.
Arup Kumar DasMechanical and Industrial Engineering Department, IIT Roorkee, Roorkee, Uttarakhand, 247667, India. arupdas80@gmail.com.
Prasanta Kumar DasDepartment of Mechanical Engineering, IIT Kharagpur, Kharagpur, West Bengal, India.
Indian Institute of Technology Roorkee · INIndian Institute of Technology Kharagpur · IN

Funding

Indian Council of Medical Research (ICMR), India award number 3-18/2015-TSIMinistry of Human Resource Development (MHRD), India award number 3-18/2015-TSI
6 · The paper itself

Abstract

Left ventricular assist devices (LVAD) emerges as an effective clinical device providing life-saving support to heart patients. The design of blood pump of an LVAD involves incredible accuracy and thorough understanding of hemodynamics to mimic the functionality of a healthy ventricle. This work studies hemodynamics around an LVAD and proposes an improved model of axial blood pump for cardiac circulation without any hemolysis complications through numerical investigations. A three-dimensional study on different versions of the impeller with three curved blades (pump I) and spiral blade (pump II) is carried out by utilizing computational fluid dynamics software ANSYS-CFX at a range of rotational speeds and flow rates. The non-Newtonian blood flow through pump is modeled by using Bird-Carreau model. To capture the change in the flow field near the rotating blade, a transient blade row model was employed. The proposal of spiral blade impeller was found to be more compatible as per the hemolytic performance. It considerably reduces the blood damage to two times lesser value than that by pump I and also improves the quality blood flow field. The spiral blade provides a guiding path to the blood particle and avoids mixing of different bloodstreams, thus reducing the eddy losses. Graphical abstract The graphical abstract shows the performance enhancement of the axial blood pump. The model proposed by Peng et al. (Comput Methods Biomech Biomed Engin 17(7):723-727, 2014) has been upgraded to two new versions by redesigning its impeller. Proposed design (pump II) shows improvement in pressure distribution (a) and reduction in hemolysis (in the case of pump II) index (b).

Indexed as

Heart-Assist DevicesModels, CardiovascularEquipment DesignHeart FailureHemodynamicsHemolysisHumansAxial blood pumpCFDDamage index estimatesHemolysisNon-Newtonian modeling

Identifiers

PMID31858420
OpenAlexW2995813004

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.