Feasibility of hybrid TomoHelical- and TomoDirect-based volumetric gradient matching technique for total body irradiation.

Chae-Seon Hong, Min-Joo Kim, Jihun Kim, Kyung Hwan Chang, Kwangwoo Park, Dong Wook Kim, Min Cheol Han, Hong In Yoon, Jin Sung Kim, Ho Lee

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Chae-Seon HongDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea.
Min-Joo KimDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea.
Jihun KimDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea.
Kyung Hwan ChangDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea.
Kwangwoo ParkDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea.
Dong Wook KimDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea.
Min Cheol HanDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea.
Hong In YoonDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea.
Jin Sung KimDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, 03722, South Korea. jinsung@yuhs.ac.
Ho LeeDepartment of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, South Korea. holee@yuhs.ac.

Funding

National Research Foundation of Korea 2017M2A2A6A01070330
6 · The paper itself

Abstract

backgroundTomotherapy-based total body irradiation (TBI) is performed using the head-first position (HFP) and feet-first position (FFP) due to treatment length exceeding the 135 cm limit. To reduce the dosimetric variation at the match lines, we propose and verify a volumetric gradient matching technique (VGMT) by combining TomoHelical (TH) and TomoDirect (TD) modes.

methodsTwo planning CT image sets were acquired with HFP and FFP using 15 × 55 × 18 cm

resultsThe TH&TD plan produced a linear gradient in junction volume, comparable to that of the TH&TH plan. D5 of the PTV was 110% of the prescribed dose when the FFP plan was shifted 0.7 cm and 1.2 cm in the superior direction for 5-GVs and 7-GVs. D95 of the PTV decreased to < 90% of the prescribed dose when the FF plan was shifted 1.1 cm and 1.3 cm in the inferior direction for 5-GVs and 7-GVs. The absolute measured dose showed a good correlation with the calculated dose in the gradient junction volume. The average percent difference (±SD) in all measured points was - 0.7 ± 1.6%, and the average dose variations between depths was - 0.18 ± 1.07%.

conclusionVGMT can create a linear dose gradient across the junction area in both TH&TH and TH&TD and can minimize the dose sensitivity to longitudinal setup errors in tomotherapy-based TBI.

Indexed as

Phantoms, ImagingComputer SimulationFeasibility StudiesHumansImage Processing, Computer-AssistedOrgans at RiskRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedWhole-Body IrradiationDose gradientField junctionSetup errorTomoDirectTomoHelicalTomotherapyTotal body irradiation

Identifiers

PMID31856870
PMCPMC6924057

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.