In one paragraph

Article in Pediatric radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Eriko MaedaDepartment of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan. NQF38509@nifty.com.
Go ShirotaDepartment of Radiology, NTT East Medical Center Tokyo, Tokyo, Japan.
Eisuke ShibataDepartment of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Shuhei KomatsuDepartment of Radiology, Tokyo Bay Urayasu Ichikawa Medical Center, Chiba, Japan.
Kenji InoImaging Center, The University of Tokyo Hospital, Tokyo, Japan.
Rumiko TorigoeCanon Medical Systems Corporation, Tokyo, Japan.
Osamu AbeDepartment of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
The University of Tokyo · JPCanon Medical Systems Corporation (Japan)NTT Medical Center · JPUniversity of Tokyo Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPediatric cardiac computed tomography (CT) can be acquired without electrode placement by using synthetic electrocardiogram (ECG).

objectiveTo determine whether the depiction of gross cardiac structures and coronary arteries in 320-row pediatric CT is not inferior when CT is gated with synthetic ECG at 150 beats per minute (bpm), compared to the patients' own ECG. MATERIALS AND

methodsSixty 320-row CT examinations performed in children younger than 3 years old with congenital cardiac anomaly were enrolled in this retrospective study. Thirty examinations were scanned using the children's own ECG for gating and 30 examinations were scanned using synthetic ECG at 150 bpm. The image quality was compared between the two gating modes using a 3-point scale to delineate the following anatomical structures: atrial septum, ventricular septum, right atrium, right ventricle, left atrium, left ventricle, main pulmonary artery, ascending aorta, aortic arch including the patent ductus arteriosus, descending aorta, right coronary artery and left main trunk. Beam-hardening artifacts from contrast enhancement material were evaluated using a 3-point scale, and the overall image quality was evaluated using a 5-point scale.

resultsSynthetic ECG was not inferior to the patients' ECG in depicting each structure, beam-hardening artifact and overall image quality. Average indices were clinically acceptable imaging quality, except for subjective image quality of mid and distal coronary arteries.

conclusionPediatric cardiac CT in patients younger than 3 years old can be acquired using synthetic ECG gating, with image quality not inferior to the patients' ECG.

Indexed as

Cardiac-Gated Imaging TechniquesElectrocardiographyFemaleHeart Defects, CongenitalHumansInfantInfant, NewbornMaleRetrospective StudiesTomography, X-Ray Computed320-row computed tomographyChildrenElectrocardiogram gatingImage qualitySedationSynthetic electrocardiogram

Identifiers

PMID31853572
OpenAlexW2995779405

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.