Evidence map›Paper›PMID 31853280›Full record

ArticleExperimental and therapeutic medicine2020

Novel detachable stents for the treatment of benign esophageal strictures.

Liang Shang, Qing-Shan Pei, Dan Xu, Ji-Yong Liu, Jin Liu

Open access · diamondAbstract read
In one paragraph

Article in Experimental and therapeutic medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Nanotechnology-based biomedical devices in the cancer diagnostics and therapy.Medical oncology (Northwood, London, England) · 2025
    Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Liang ShangDepartment of Gastrointestinal Surgery, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong 250021, P.R. China.
Qing-Shan PeiDepartment of Gastroenterology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong 250021, P.R. China.
Dan XuEndoscopy Room, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong 250021, P.R. China.
Ji-Yong LiuDepartment of Gastroenterology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong 250021, P.R. China.
Jin LiuDepartment of Gastroenterology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong 250021, P.R. China.
Shandong Provincial Hospital · CNShandong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The radial force of esophageal stents may not completely change during extraction and therefore, the procedure of stent removal may cause tissue damage. The present study reports the manufacture of 2 novel detachable stents, which were designed to reduce tissue damage through their capacity to be taken or fall apart prior to removal and evaluated the supporting properties of these stents and the extent of local mucosal injury during their removal. The stents were manufactured by braiding, heat-setting, coating and connecting. The properties of the stents were evaluated by determining the following parameters: Expansion point, softening point, stent flexibility, radial compression ratio and radial force. A total of 18 rabbits with induced esophageal stricture were randomly assigned to 3 groups as follows: Detachable stent (DS) group, biodegradable stent (BS) group and control group. The stricture rate, complications, survival, degradation and stent removal were observed over 8 weeks. The stents of the DS and BS groups provided a similar supporting effect. The stricture rate, incidence of complications and survival were also similar between the 2 groups, while significant differences were noted between the DS and control groups and between the BS and control groups. In the BS group, the stents were degraded and moved to the stomach within 7 weeks (2 in 6 weeks and 3 in 7 weeks). The debris was extracted using biopsy forceps. In the DS group, all stents were easy to remove and 2 cases exhibited minor hemorrhage. In conclusion, the 2 types of novel detachable stent provided an equally efficient supporting effect

Indexed as

animal experimentationendoscopic procedureesophageal stricturestents

Identifiers

PMID31853280
PMCPMC6909791
OpenAlexW2983607271

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.