Article in The Journal of arthroplasty, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Secondary Infection of Adverse Local Tissue Reaction Leading to Amputation in a Patient With a Modular Knee Endoprosthesis.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2025
    Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Cody C WylesDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN.
Christopher R ParadiseDepartment of Orthopedic Surgery, Mayo Clinic, Graduate School of Biomedical Sciences, Rochester, MN.
Thao L MastersDivision of Clinical Microbiology, Mayo Clinic, Rochester, MN.
Robin PatelDivision of Clinical Microbiology, Mayo Clinic, Rochester, MN.
Andre J van WijnenDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN.
Matthew P AbdelDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN.
Robert T TrousdaleDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN.
Rafael J SierraDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN.
Mayo Clinic in Arizona · US

Funding

Musculoskeletal Research Training ProgramT32AR056950 · NIAMS · MAYO CLINIC ROCHESTER · PI Jennifer J Westendorf · 2009 to 2026
$7.0M
NIAMS NIH HHS T32 AR056950
6 · The paper itself

Abstract

backgroundThe aims of this study were to determine the levels of cobalt (Co) and chromium (Cr) ions generated in simulators from metal-on-polyethylene (MoP) and ceramic-on-polyethylene (CoP) constructs. Furthermore, we aimed to investigate the cytotoxic effect of these ion levels on native tissues and their potential to modify periprosthetic joint infection risk.

methodsWe used in vitro culture of human adipose-derived mesenchymal stem cells (AMSCs) and Staphylococcus epidermidis cultures, respectively. Ten hip simulator constructs (5 MoP and 5 CoP) were assembled and run for 1,000,000 cycles in bovine serum and evaluated for CoCr concentration. Cytotoxicity and growth impact on AMSCs and S. epidermidis was compared between CoCr and inert silicon dioxide.

resultsAfter 1,000,000 cycles, mean MoP and CoP Co concentration was 2264 and 0.6 ng/mL, respectively (P < .001). Mean MoP and CoP Cr concentration was 217 and 4.3 ng/mL, respectively (P < .001). Mean MoP Co:Cr ratio was 10:1. Co ions were significantly more toxic to human AMSCs than control silicon dioxide in a dose-response manner (P < .001). S. epidermidis growth was not significantly impacted by Co concentrations observed in the simulators.

conclusionMoP constructs built in ideal conditions generated substantial CoCr debris, highlighting a baseline risk with these implants that may be exacerbated by host factors or imperfect surgical technique. Evaluation of impact on AMSCs suggests that debris levels produced under simulator conditions can be cytotoxic. In addition, these concentrations did not potentiate or inhibit S. epidermidis growth, suggesting that elevated periprosthetic joint infection rates with adverse local tissue reaction are related to other factors potentially associated with tissue necrosis.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisAnimalsCattleCeramicsChromiumCobaltHumansIonsPolyethyleneProsthesis DesignChromiumCobaltIonsPolyethylenecobaltionsperiprosthetic joint infectionsimulatortotal hip arthroplastytrunnionosis

Identifiers

PMID31852609
PMCPMC7085456
OpenAlexW2990585232

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.