Evidence map›Paper›PMID 31850397›Full record

ArticleNature electronics2019

A miniaturized multi-clamp CMOS amplifier for intracellular neural recording.

Siddharth Shekar, Krishna Jayant, M Angeles Rabadan, Raju Tomer, Rafael Yuste, Kenneth L Shepard

Abstract read
In one paragraph

Article in Nature electronics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Time for NanoNeuro.Nature methods · 2021
    Review
  3. Frequency-Division Multiplexing with Graphene Active Electrodes for Neurosensor Applications.IEEE transactions on circuits and systems. II, Express briefs : a publication of the IEEE Circuits and Systems Society · 2021
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Siddharth ShekarDepartment of Electrical Engineering, Columbia University, New York, NY 10027, USA.
Krishna JayantDepartment of Electrical Engineering, Columbia University, New York, NY 10027, USA.
M Angeles RabadanDepartment of Biological Sciences, Columbia University, New York, NY 10027, USA.
Raju TomerDepartment of Biological Sciences, Columbia University, New York, NY 10027, USA.
Rafael YusteDepartment of Biological Sciences, Columbia University, New York, NY 10027, USA.
Kenneth L ShepardDepartment of Electrical Engineering, Columbia University, New York, NY 10027, USA.

Funding

IMAGING FUNCTIONAL CONNECTIVITY IN VISUAL CORTEXR01EY011787 · NEI · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI YUSTE, RAFAEL · 1998 to 2021
$6.4M
Single Molecule Real Time Electronic SequencingR01HG006882 · NHGRI · INTEL LABS · PI LEMAY, SERGE GUY, SHEPARD, KENNETH L · 2012 to 2015
$5.0M
Functional connectomics of the neocortical microcircuitDP1EY024503 · NEI · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI YUSTE, RAFAEL · 2013 to 2017
$4.0M
Optimizing flexible, active electrode arrays for chronic, large-scale recording and stimulation on the scale of 100,000 electrodesU01NS099697 · NINDS · DUKE UNIVERSITY · PI BRAUN, PAUL, PESARAN, BIJAN · 2016 to 2018
$3.5M
Effect of GABAergic inhibition of dendritic spines on synaptic pruning in the medial prefrontal cortex during adolescenceR01MH115900 · NIMH · SUNY DOWNSTATE MEDICAL CENTER · PI SMITH, SHERYL S · 2019 to 2023
$3.2M
Deep brain photoacoustic tomography at single-neuron resolution using arrays of photonic emitters and high-frequency ultrasound transducersU01NS099717 · NINDS · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI ROUKES, MICHAEL L, SHEPARD, KENNETH L · 2016 to 2018
$3.0M
Functional consequences of GABAergic inhibition of dendritic spines at pubertyR01MH100561 · NIMH · SUNY DOWNSTATE MEDICAL CENTER · PI SMITH, SHERYL S · 2013 to 2017
$3.0M
Wide Deployment of Massively Multiplexed Nanosystems for Brain Activity MappingU01NS099726 · NINDS · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI ROUKES, MICHAEL L, SHEPARD, KENNETH L · 2016 to 2018
$2.9M
Integrated Microphysiological System of Cerebral Organoid and Blood Vessel for Disease Modeling and Neuropsychiatric Drug screeningUG3TR002151 · NCATS · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI LEONG, KAM W · 2018 to 2019
$2.6M
A comparative approach for decomposing the mammalian brain architectural complexityDP2MH119423 · NIMH · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI TOMER, RAJU · 2018 to 2018
$2.4M
Two-photon optical control of astrocytic functionR01MH101218 · NIMH · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI YUSTE, RAFAEL · 2013 to 2017
$2.0M
Enzyme-less DNA base discrimination using solid-state nanopores with high-frequency integrated detection electronicsR01HG009189 · NHGRI · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI DRNDIC, MARIJA, SHEPARD, KENNETH L · 2016 to 2018
$1.2M
NCATS NIH HHS UG3 TR002151NEI NIH HHS DP1 EY024503NEI NIH HHS R01 EY011787NHGRI NIH HHS R01 HG006882NHGRI NIH HHS R01 HG009189NIMH NIH HHS DP2 MH119423NIMH NIH HHS R01 MH100561NIMH NIH HHS R01 MH101218NIMH NIH HHS R01 MH115900NINDS NIH HHS R01 NS110422NINDS NIH HHS U01 NS099697NINDS NIH HHS U01 NS099717NINDS NIH HHS U01 NS099726
6 · The paper itself

Abstract

Intracellular electrophysiology is a foundational method in neuroscience and uses electrolyte-filled glass electrodes and benchtop amplifiers to measure and control transmembrane voltages and currents. Commercial amplifiers perform such recordings with high signal-to-noise ratios (SNRs) but are often expensive, bulky, and not easily scalable to many channels due to reliance on board-level integration of discrete components. Here, we present a monolithic complementary-metal-oxide-semiconductor (CMOS) multi-clamp amplifier integrated circuit capable of recording both voltages and currents with performance exceeding that of commercial benchtop instrumentation. Miniaturization enables high-bandwidth current mirroring, facilitating the synthesis of large-valued active resistors with lower noise than their passive equivalents. This enables the realization of compensation modules that can account for a wide range of electrode impedances. We validate the amplifier's operation electrically, in primary neuronal cultures, and in acute slices, using both high-impedance sharp and patch electrodes. This work provides a solution for low-cost, high-performance and scalable multi-clamp amplifiers.

Identifiers

PMID31850397
PMCPMC6913532

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.