ArticleArtificial organs2020
The impact of shear stress on device-induced platelet hemostatic dysfunction relevant to thrombosis and bleeding in mechanically assisted circulation.
Article in Artificial organs, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it, 50 citations in OpenAlex.
- Hemocompatibility of Mechanical Circulatory Support Devices: An Integrated Review of Platelet Function Assessment in In-Vitro Blood Experiments.Annals of biomedical engineering · 2026Pooled it
- Device-Induced Blood Damage in Pump-Assisted Circulation: A Comparative Study of HeartMate III and BrioVAD Pumps.Artificial organs · 2026Article
- Selective Inhibition of Integrin β3 Topology Provides a Safer Antithrombotic Strategy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Large Animal Models for Preclinical Evaluation of Heart Valve Prostheses, Left Ventricular Assist Devices and Total Artificial Hearts: A Narrative Review.Biomimetics (Basel, Switzerland) · 2026Review
- Platelet Adhesion and Aggregation Dynamics over Collagen- and VWF-coated Surfaces: Insights from Dissipative Particle Dynamics Simulations and Microfluidic Experiments.Bulletin of mathematical biology · 2026Article
- Polymeric Fibrous Materials for Procoagulant and Anticoagulant Applications: A Review of Molecular Blood-Material Mechanisms and Strategies.Materials (Basel, Switzerland) · 2026Review
- Influence of side-hole configuration on recirculation in dual-lumen cannulas for veno-venous extracorporeal membrane oxygenation: a parametric computational fluid dynamics study.Frontiers in bioengineering and biotechnology · 2026Article
- Feasibility and Safety of Cytosorb Application in Patients With Acute Liver Failure.Liver international : official journal of the International Association for the Study of the Liver · 2025Article
- In Vitro Comparison of Device-Induced Hemolysis, Platelet Defects, and von Willebrand Factor Degradation Between the HeartMate 2 and HeartMate 3 Pumps.Artificial organs · 2025Article
- A Biophysics-Based Mathematical Model of Shear-Induced Platelet Activation and Receptor Shedding: Re-Examining Previous Experimental Data.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2025Article
- GPVI-dependent functional competence of buffy coat platelet concentrates (PCs) versus PRP-derived PCs: insights into the effects of biomechanical forces during platelet preparation.Annals of hematology · 2025Article
- In vitro study on device-induced damage to blood cellular components and degradation of von Willebrand factor in a CentriMag pump-assisted circulation.Artificial organs · 2024Article
- Acquired platelet defects are responsible for nonsurgical bleeding in left ventricular assist device recipients.Artificial organs · 2022Article
- Computational fluid dynamics analysis and experimental hemolytic performance of three clinical centrifugal blood pumps: Revolution, Rotaflow and CentriMag.Medicine in novel technology and devices · 2022Article
- Comparison of the Hemocompatibility of an Axial and a Centrifugal Left Ventricular Assist Device in an In Vitro Test Circuit.Journal of clinical medicine · 2022Article
- A New Mathematical Numerical Model to Evaluate the Risk of Thrombosis in Three Clinical Ventricular Assist Devices.Bioengineering (Basel, Switzerland) · 2022Article
- Validation of a Miniaturized Test Loop for the Assessment of Human Blood Damage by Continuous-Flow Left-Ventricular Assist Devices.Annals of biomedical engineering · 2021Article
- Device-Induced Hemostatic Disorders in Mechanically Assisted Circulation.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/HemostasisReview
Corrections and comments
- Erratum issued
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
The aim of this study was to examine the impact of the nonphysiological shear stress (NPSS) on platelet hemostatic function relevant to thrombosis and bleeding in mechanically assisted circulation. Fresh human blood was circulated for four hours in in vitro circulatory flow loops with a CentriMag blood pump operated under a flow rate of 4.5 L/min against three pressure heads (70 mm Hg, 150 mm Hg, and 350 mm Hg) at 2100, 2800, and 4000 rpm, respectively. Hourly blood samples from the CentriMag pump-assisted circulation loops were collected and analyzed for glycoprotein (GP) IIb/IIIa activation and receptor shedding of GPVI and GPIbα on the platelet surface with flow cytometry. Adhesion of platelets to fibrinogen, collagen, and von Willebrand factor (VWF) of the collected blood samples was quantified with fluorescent microscopy. In parallel, mechanical shear stress fields within the CentriMag pump operated under the three conditions were assessed by computational fluid dynamics (CFD) analysis. The experimental results showed that levels of platelet GPIIb/IIIa activation and platelet receptor shedding (GPVI and GPIbα) in the blood increased with increasing the circulation time. The levels of platelet activation and loss of platelet receptors GPVI and GPIbα were consistently higher with higher pressure heads at each increasing hour in the CentriMag pump-assisted circulation. The platelet adhesion on fibrinogen increased with increasing the circulation time for all three CentriMag operating conditions and was correlated well with the level of platelet activation. In contrast, the platelet adhesion on collagen and VWF decreased with increasing the circulation time under all the three conditions and was correlated well with the loss of the receptors GPVI and GPIbα on the platelet surface, respectively. The CFD results showed that levels of shear stresses inside the CentriMag pump under all three operating conditions exceeded the maximum level of shear stress in the normal physiological circulation and were strongly dependent on the pump operating condition. The level of platelet activation and loss of key platelet adhesion receptors (GPVI and GPIbα) were correlated with the level of NPSS generated by the CentriMag pump, respectively. In summary, the level of NPSS associated with pump operating condition is a critical determinant of platelet dysfunction in mechanically assisted circulation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.