Evidence map›Paper›PMID 31847062›Full record

ArticleSensors (Basel, Switzerland)2019

Foot Plantar Pressure Measurement System Using Highly Sensitive Crack-Based Sensor.

Jieun Park, Minho Kim, Insic Hong, Taewi Kim, Eunhan Lee, Eun-A Kim, Jae-Kwan Ryu, YongJin Jo, Jeehoon Koo, Seungyong Han and 2 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Jieun ParkDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.
Minho KimDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.
Insic HongDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.
Taewi KimDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.
Eunhan LeeDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.
Eun-A KimDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.
Jae-Kwan RyuUnmanned/Robotics Team 1, LIG Nex1, 207, Mabuk-ro, Giheung-gu, Yongin 446-798, Korea.ORCID 0000-0003-4176-3867
YongJin JoUnmanned/Robotics Team 1, LIG Nex1, 207, Mabuk-ro, Giheung-gu, Yongin 446-798, Korea.ORCID 0000-0002-3749-7570
Jeehoon KooUnmanned/Robotics Team 1, LIG Nex1, 207, Mabuk-ro, Giheung-gu, Yongin 446-798, Korea.
Seungyong HanDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.ORCID 0000-0003-2870-4088
Je-Sung KohDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.ORCID 0000-0002-7739-0882
Daeshik KangDepartment of Mechanical Engineering, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-749, Korea.ORCID 0000-0002-7490-9079

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Measuring the foot plantar pressure has the potential to be an important tool in many areas such as enhancing sports performance, diagnosing diseases, and rehabilitation. In general, the plantar pressure sensor should have robustness, durability, and high repeatability, as it should measure the pressure due to body weight. Here, we present a novel insole foot plantar pressure sensor using a highly sensitive crack-based strain sensor. The sensor is made of elastomer, stainless steel, a crack-based sensor, and a 3D-printed frame. Insoles are made of elastomer with Shore A 40, which is used as part of the sensor, to distribute the load to the sensor. The 3D-printed frame and stainless steel prevent breakage of the crack-based sensor and enable elastic behavior. The sensor response is highly repeatable and shows excellent durability even after 20,000 cycles. We show that the insole pressure sensor can be used as a real-time monitoring system using the pressure visualization program.

Indexed as

Foot OrthosesEquipment DesignGaitHumansModels, TheoreticalPressurePrinting, Three-Dimensionalcrack-based sensorfoot plantar pressureinsole pressure sensorpressure measurement system

Identifiers

PMID31847062
PMCPMC6960515

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.