ArticleMagnetic resonance in medicine2020
First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz.
Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 58 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
58 citing papers in PubMed.
- Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.Magnetic resonance in medicine · 2026Article
- SAR validation of RF coils and implants in a B0-free RF safety laboratory.Medical physics · 2026Article
- A Numerical Alternative to MR Thermometry for Safety Validation of Multi-Channel RF Transmit Coils.Magnetic resonance in medicine · 2026Article
- Evaluation of the diffusion time dependence of the IVIM effect based on realistic capillary flow simulations in mouse brain.Magma (New York, N.Y.) · 2026Article
- Comprehensive 4D Parallel Transmission Spatial-Spectral Pulse Design for Slab-Selective Uniform Water-Selective Excitation: Demonstration in the Human Brain at 7 Tesla.Magnetic resonance in medicine · 2026Article
- First In VivoMagnetic resonance in medicine · 2026Article
- On the Impact of Artifacts Induced by Mismatches Between Auto-Calibration Signal and Accelerated 3D GRE Data at 11.7T.Magnetic resonance in medicine · 2026Article
- Advancing whole-brain BOLD functional MRI in humans at 10.5 T with motion-robust 3D echo-planar imaging, parallel transmission, and high-density radiofrequency receive coils.Magnetic resonance in medicine · 2026Article
- Human fMRI at 11.7T: Assessing feasibility, stability, and reliability on the Iseult scanner.Imaging neuroscience (Cambridge, Mass.) · 2026Article
- The Mode of Operation of High-Impedance Coils and Shielded Coaxial Cable Coils: A Comparative Study.NMR in biomedicine · 2025Article
- Compressed Sensing-Accelerated Free-Breathing Liver MRI at 7 T.NMR in biomedicine · 2025Article
- A 128-channel receive array with enhanced signal-to-noise ratio performance for 10.5T brain imaging.Magnetic resonance in medicine · 2025Article
- Parallel-transmission spatial spectral pulse design with local specific absorption rate control: Demonstration for robust uniform water-selective excitation in the human brain at 7 T.Magnetic resonance in medicine · 2025Article
- Exploring in vivo human brain metabolism at 10.5 T: Initial insights from MR spectroscopic imaging.NeuroImage · 2025Article
- RF coil design strategies for improving SNR at the ultrahigh magnetic field of 10.5T.Magnetic resonance in medicine · 2025Article
- 3D Metamaterials Facilitate Human Cardiac MRI at 21.0 Tesla: A Proof-of-Concept Study.Sensors (Basel, Switzerland) · 2025Article
- Macrovascular contributions to resting-state fMRI signals: A comparison between EPI and bSSFP at 9.4 Tesla.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- In vivo imaging of the human brain with the Iseult 11.7-T MRI scanner.Nature methods · 2024Article
- Acoustic noise reduction in the NexGen 7 T scanner.Magnetic resonance in medicine · 2024Article
- A Quantitative Comparison ofSensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
purposeTo investigate the feasibility of imaging the human torso and to evaluate the performance of several radiofrequency (RF) management strategies at 10.5T.
methodsHealthy volunteers were imaged on a 10.5T whole-body scanner in multiple target anatomies, including the prostate, hip, kidney, liver, and heart. Phase-only shimming and spoke pulses were used to demonstrate their performance in managing the
resultsHigh-quality images were acquired and demonstrated excellent overall contrast and signal-to-noise ratio. The experimental results matched well with predictions and suggested good translational capabilities of the RF management strategies previously developed at 7T. Phase-only shimming provided increased efficiency, but showed pronounced limitations in homogeneity, demonstrating the need for the increased degrees of freedom made possible through single- and multispoke RF pulse design.
conclusionThe first in-vivo human imaging was successfully performed at 10.5T using previously developed RF management strategies. Further improvement in RF coils, transmit chain, and full integration of parallel transmit functionality are needed to fully realize the benefits of 10.5T.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.